CAUTION! Danger of material damage!
Improper transport or temporary storage can
result in damage to the product.
• Always transport the pump with care.
• Drain the pump prior to storage.
• Store the pump somewhere dry and frost-free.
• Observe the operating instructions of the com-
bustion engine.
Draining the pump for temporary storage
• Switch off the pump and secure it against being
switched back on again.
• Open the access/drain opening and drain the
water entirely.
• Close the access/drain opening again.

4 Intended use

The pumps of the Wilo-Drain LPC series are for
pumping wastewater with a low proportion of
solid particles. Areas of application:
• Draining excavation ditches
• Draining ponds
• Pumping out seepage water
• Spraying/irrigation of gardens and lawns
WARNING! Danger of suffocation!
The exhaust fumes of combustion engines are
toxic. There is a danger of suffocation if they are
inhaled. Only use pumps with combustion
engines outdoors, never indoors!
WARNING! Health hazard!
Due to the materials used, the pump is not suit-
able for pumping drinking water! Contamination
5.2

Technical Data

Pump
Suction port / discharge port
Max. Korngröße
Housing material
Impeller material
Material of mechanical seal
Material of static seal

Electric motor

Rated motor power P
2
Rated current
Frequency
Winding
Speed
Insulating material class
Protection class
Operating mode
Cooling
Installation and operating instructions Wilo-Drain LPC
LPC 40
G 1 1/2" (DN40)
< 4 mm
Cast aluminium
EN-GJL-250
Carbon / aluminium oxide
NBR
See data plate
See data plate
50 Hz
Three-phase current 230 - 400 V
2900 rpm
F
IP55
S1
Air cooling
with wastewater poses a health hazard. Do not
use pumps for drinking water!
CAUTION! Danger of material damage!
Pumping impermissible substances can damage
the product. Never pump water containing salt
or chlorine and never pump substances such as
rough paper, rubble, waste, animal waste, long-
fibred material or swimming pool water!
Proper use includes following these instructions.
Any other use is considered improper.

5 Product details

5.1 Type key
Example:
LPC 40/19 3-400-50-2 M
LP
Self-priming pump (lifting pump)
C
Grey cast iron
40
Nominal width (DN 40)
/19
Maximum delivery head [m]
3-400
Electric motor: 3~400 V
-50
Frequency 50 Hz
-2
2-pole
M
Mobile: version with trolley
Example:
LPC 40/27 PM
LP
Self-priming pump (lifting pump)
C
Grey cast iron
40
Nominal width (DN 40)
/27
Maximum delivery head [m]
P
Petrol: four-stroke combustion engine (petrol)
M
Mobile: version with trolley
LPC 50
G 2" (DN50)
< 4 mm
Grey cast iron EN-GJL-250
EN-GJL-250
Carbon / aluminium oxide
NBR
LPC 80
G 3" (DN80)
< 4 mm
Grey cast iron EN-GJL-250
EN-GJL-250
SiC / SiC
NBR