Connection Of A Gate Motor; Using; Using The Interphone; Indoor Unit Settings - Extel WEPA 245 SER.R2 Guide D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 4
c. Connection of a gate motor
Connect directly the gate motor to the terminals
The roadside panel supplies a current-free "dry" contact to connect to the "push button" control of your auto-
matic gate opener.
NB: this function is only operational if communication is established with the roadside panel.
d. Connecting one or two optional extra WEPACB 247 BIS SER.R2 indoor station
1. Connect the wires as shown in the connection plan (fig.6)
2. To connect the indoor station to the extra WEPACB 247 BIS SER.R2, indoor station, 2 wires are needed for all
the functions.
1st optional indoor station:
• Terminal «3» of the response unit on terminal «3» of the extra indoor station
• Terminal «4» of the response unit on terminal «4» of the extra indoor station
2nd optional indoor station:
• Terminal «5» of the response unit on terminal «5» of the extra indoor station
• Terminal «6» of the response unit on terminal «6» of the extra indoor station
Cable calibre : • 2 x 1,5 mm
Caution : In any case, do not double the wires to increase size

6. USING

a. Using the interphone
• A call on the roadside panel will trigger an audible signal on the answering unit. You have 30 sec. to answer.
Press the key
to communicate with your visitor.
One press of the
button is enough to establish communication with the street plate.
• The keeper or electric lock is controlled using the
• The mechanism is controlled using the
• The "Monitoring" function (for listening to the street) is controlled using the
* in "communication" mode only
b. Indoor unit settings
3 adjustments can be accessed on the side of the indoor unit:
• Cut ringing (0). The
• Melody select (1-Ding dong, 2- La lettre à Elise or 0-mute) (8).
• Melody volume control

7. TECHNICAL SPECIFICATIONS

a. Indoor unit
(PACB 247 SER.R2)
• Reference: 812245
• Power supply: 17 V
• Consumption : 17 W
• Dimensions (mm): 150x120x31
b. Power supply
• Adapter: 100-240 V~ / 50-60Hz / 17V
If the power supply cable has to be cut, ensure that the colour coding of the wires is maintained when reconnecting (red
wire (+) (fig. 7)).
c. Outdoor unit
(PAPL A 245 SER.R2)
• Reference: 822245
• Operating temperature: from -10°C to +45°C.
• Protection Index: IP44
• Front dimension (mm) :115x152x37
(fig. 6)
2
wires up to 25 m
* button.
(fig.2)
indicator then blinks on the front of the indoor unit.
(9).
/ 1500 mA
CFI EXTEL WEPA 245 SER.R2 - 12/2012
at the back of the roadside panel.
* button.
(fig.6)
button.
GB4

Publicité

Table des Matières
loading

Table des Matières