ALCOvE iNSTALLATiON

Your appliance may be installed, using a listed double wall connector, such as Security DL6 in Canada, the
Simpson Duravent Plus DVL in the USA or an equivalent double wall connector, into an alcove having a depth
of no more than 4 feet (1.2m) and a height of at least 75" (1.9m). The minimum clearances are as shown.
(203mm)
Parallel & Corner
CEILING (F)
noTe: minimum width 64" (1626mm), Minimum depth 32" (813mm), Maximum depth 48" (1219mm)
3.4

FLOOr PrOTECTiON

If the appliance is to be installed on top of a combustible floor, it must be placed on an approved non-combus-
tible hearth pad, that extends 8" (203mm) beyond the appliance sides and back and 18" (457mm) to the front.
The reduced clearance from the back of the appliance may result in the appliance pad terminating shorter than
8" (203mm) beyond the appliance.
noTe: Floor protection is required for spark and ash shielding, but not for limiting floor temperatures
from the radiant heat of the appliance. the appliance was designed and safety tested so that without
any protection, the floor would not overheat.
Refer to local building codes for suitable floor protection materials.
K
J
J
I
BACK WALL
8"
C
16"
D
(406mm)
A
17⅜"
B
(441mm)
28
/
"
7
8
(733mm)
ALCOVE
single wall ConneCTor
FronT (i)
CANADA
18" (457mm)
USA
16" (406mm)
noTe: if a section of horizontal chimney connector is used, floor protection is
required under the chimney connector and 2" (51mm) beyond each side.
BACK WALL
E
4 FOOT (1.2m)
E
MAX
alCove
N/A
minimUm Floor ProTeCTion
siDes (J)
8" (203mm)
8" (203mm)
CEILING
F
G
H
FLOOR
Double Wall ConneCtor
84" (2.13m)
baCK (K)
8" (203mm)
8" (203mm)
W415-1133 / A / 06.12.13
9
EN