OUTSiDE Air

EN
iF rooM air starvation oCCurs beCause the Fresh air intaKe is bloCKeD With iCe,
leaves, etC., or beCause the applianCe Door Was leFt open, or Due to a strong
eXhaust Fan operating etC., Dangerous FuMes anD sMoKe FroM the operating
The following are signs that a fresh air kit may be required:
When there is combustion present: Wood burns poorly, smoke spills, back-draft takes place and your
chimney does not draw steadily.
In the winter there is too much condensation on the windows.
Opening a window seems to alleviate the above symptoms.
A ventilation system is installed in the house.
Other devices are present that exhaust house air.
The house has tight fitting windows and/or is equipped with a well-sealed vapour barrier.
3.6

ELECTriCAL SUPPLY

all Wiring Must be Done by a QualiFieD eleCtriCian anD shall be in CoMplianCe With
loCal CoDes. in the absenCe oF loCal CoDes, use the Current Csa C22.1
CanaDian eleCtriC CoDe (in CanaDa) or the ansi/nFpa no. 70 national eleCtriC CoDe
The blower motor for this appliance runs on standard 120 VAC power. The appliance comes equipped with a 3
prong plug on the end of a 6 foot (1.83m) power cord. The power cord exits the rear right corner of the furnace
3.5" (89mm) from the floor. A household 120 VAC receptacle on a minimum 15 Amp circuit is required within
reach of the power cord when furnace is in its final installation location. DO NOT CONNECT POWER CORD
THROUGH ExTENSION CORD OR POwER BAR.

3.6.1 ELECTriCAL SCHEmATiC (FACTOrY wirED)

THREE PRONG
PLUG
W415-1133 / A / 06.12.13
applianCe CoulD be DraWn into the rooM.
VARIABLE
SPEED
CONTROL
M
BLOWER
MOTOR
WARNING
!
WARNING
!
in The UniTeD sTaTes.
1
2
3
4
5
WARNING
!
WARNING
!
BI-METAL
THERMAL
DISK SWITCH
CHASSIS