6.0 OPTiONS

6.1

ExTErNAL BLOwEr CONTrOL

turn oFF eleCtriCal poWer beFore serviCing this applianCe.
Use onlY wolF sTeel aPProveD oPTional aCCessories anD rePlaCemenT ParTs wiTh
this applianCe. using non-listeD aCCessories (bloWers, Doors, louvres, triMs, gas
ComPonenTs, venTing ComPonenTs, eTC.) CoUlD resUlT in a saFeTY haZarD anD will
ensUre ThaT The Power CorD is noT in ConTaCT wiTh anY sUrFaCe oF The aPPlianCe
to prevent eleCtriCal shoCK or Fire DaMage. Do not run the poWer CorD beneath
all Wiring Must be Done by a QualiFieD eleCtriCian anD shall be in CoMplianCe With
loCal CoDes. in the absenCe oF loCal CoDes, use the Current Csa C22.1 CanaDian
eleCtriC CoDe (in CanaDa) or the ansi/nFpa no. 70 national eleCtriC CoDe in the
all CoMponents in CirCuit Must be rateD For MiniMuM 120v, 15 aMp serviCe anD
all CirCuit Wire Must have an insulation rating oF no less than 194°F (90°C),
anD all strain relieF, ConDuCtor support anD proteCtive sheathing Must be
DeterMineD by QualiFieD eleCtriCian perForMing installation anD in aCCorD With
all CirCuit CoMponents WhiCh are loCateD above the eXit point oF the FurnaCe
(The sTrain relieF FiTTing) mUsT mainTain ClearanCe To all PoinTs on The FUrnaCe
The same or greaTer ClearanCes To The aPPlianCe as DeFineD in seCTion 3.2.
To PrevenT heaT Damage To line volTage wire insiDe FUrnaCe, KeeP minimUm
ClearanCe betWeen bloWer Division plate anD line voltage CirCuit.
The blower can be further controlled by installing an external wall switch or line voltage thermostat. This will
allow manual on/off control of the blower from a more convenient location or automatic on/off control based on
room temperature.
This can be done by replacing the jumper wire between terminals #3 and #4 on the control block terminal strip
(inside lower junction box) with a line voltage circuit.
to access the Control block terminal strip:
BLOwER
DIVISION PLATE
LOwER REAR kNOCk OUTS ON SIDE PANELS
risK oF Fire anD eleCTriCal shoCK.
voiD The warranTY anD CerTiFiCaTion.
CertiFieD by aCCepteD eleCtriCal authority (e.g. Csa, ul).
eleCTriCal CoDes.
VARI-SPEED
CONTROL
WARNING
!
The aPPlianCe.
UniTeD sTaTes.
LOwER
JUNCTION BOx
19
h51.1
PLASTIC GROMMET
REPLACE JUMPER
wIRE BETwEEN
TERMINALS #3 & #4
wITH LINE VOLTAGE
wIRE
NOTE - Most wiring
omitted for drawing clarity.
LOwER JUNCTION
BOx wITH COVER
REMOVED-CONTROL
BLOCk TERMINAL
STRIP ExPOSED.
W415-1133 / A / 06.12.13