SmOkiNg

A properly installed appliance should not smoke. If yours does, check the following:
Has the chimney had time to get hot?
Is the smoke passage blocked anywhere in the appliance, chimney connector or chimney?
Is the room too airtight and the air intake not connected to the outside? Try with a window partly open.
Is the smoke fl ow impeded by too long a horizontal pipe or too many bends?
Is it a weak draft perhaps caused by a leaky chimney, a cold outside chimney, too large a diameter of a
chimney, too short a chimney, or a chimney too close to trees or a higher roof?
7.6

BLOwEr OPErATiON

The TF100 comes with a circulation blower which is connected through a variable speed control mounted on
the rear panel of the furnace (lower right side corner). Once this control has been turned on (turn knob clock-
wise from its "OFF" position, note: fan speed is reduced as the knob is turned further in the clockwise direction)
cycling of the fan is controlled by a thermal switch located at the rear of the firebox. The fan will cycle on when
the firebox reaches 49°C (120°F) and off when the temperature drops below 39°C (102°F).
VARI-SPEED
BLOwER CONTROL