7. Life phases
Coupling/motor adapter/motor
A motor with or without gear can be connected to the end elements. Correct sizing of the drive
will prevent dangers arising from this linear unit.
The motor is adapted via a motor adapter consisting of motor plate/s and coupling housing, plus
a coupling. This matched combination ensures that the components are aligned axially. The
motor/linear shaft combination determines the motor adapter version. The installation follows a
logical sequence. The coupling is fastened to the drive and plugged through the installed motor
adapter on to the pins of the linear unit. The coupling lug is pulled on to the pins of the linear unit
through the installation opening in the coupling housing. One or two motor plates are used,
depending on the version.
The end caps of the tubular guide must be adapted to the drive side. The width of the motor
adapter component's coupling flange is important.
Centring rings must be used in some versions. This interface is stipulated for motor types from
RK Rose+Krieger GmbH's RK product range. A selection matrix in the Linear Components
catalogue shows the right adaptation.
The customer may design different combinations at its own discretion and risk.
Motor
Motor plates

7.2.5 Motor limiting table

Version
EP-II 18 / EPX-II 18
EP-II 30 / EPX-II 30
EP-II 40 / EPX-II 40
EP-II 50 / EPX-II 50
EP-II 60 / EPX-II 60
EP-II 80 / EPX-II 80
40
Coupling housing
Max. motor weight in kg
-
8
16
16
16
16
Coupling
Mass point in mm
-
400
400
400
400
400