7. Working life

7.2.5 Motor limiting table

Version
Max. motor weight in kg
Centre of gravity distance
in mm
RK MultiLine II Z
16
400
Transfer units
Linear units arranged in parallel must be matched to the transfer shaft to transfer torques. This
can - just as with the motor - be fixed to the steering with couplings, depending on the version.
If the designed installation length is greater than the maximum installation length or maximum
speed determined from the "estimated shaft design" formula, then a stationary bearing support
is used to absorb the corresponding loads.
Estimated shaft design:
max. installation length [mm] = (2720 - speed [min-1]) + 2 x 107.5
max. speed [min-1] = 2720 - L [mm]
The interface combinations determined by RK Rose+Krieger GmbH from coupling and transfer
unit are binding.
without protection
with protection
Steering
Stationary bearing support
Steering