Installation With Fixings; Installing The Optional Accessories - RK Rose+Krieger EP-II Notice D'assemblage

Système tubulaire de l'unité linéaire
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

7. Life phases

7.2.3 Installation with fixings

Horizontal installation
The specific tightening torques for the screws must be
observed during all assembly work. Note the strength of the
screws and separate information for accessories supplied.
Only compliance with the conditions guarantee the safety
and long working life of the linear shaft. Take the values
from the table in these instructions.
Sliding block fixings
This linear unit can be fastened by screwing the end
elements to a suitable sub-structure.
Vertical installation

7.2.4 Installing the optional accessories

Diagram shows EP-II 40
Mechanical limit switch
The technical specifications for limit switches can be found in the catalogue. Ensure that the
wiring is safely laid out during installation. Avoid damage to the wiring, for example by having
radii that are too small, as this can lead to failure of the system. The wiring must not be in the path
travelled by the linear unit.
The limit switch is installed via a track that can be fastened to the linear unit's end elements using
fixing elements. The limit switches can be axially moved on and affixed to the rails.
39

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Epx-ii

Table des Matières