Display elements and function keys
Display elements and function keys
P A R 2 0 V L V I M A X D B T E M P
P A R 1
S E T
S H
8201BB operating module
Key functions
Key
Function
PRG
Change between operating level and code level
SH
Change between code level and parameter level
L
Increase displayed value
M
Reduce displayed value
SH + L
Scroll up displayed value
SH + M
Scroll down displayed value
Save modification (save every parameter individually before disconnecting the controller
SH + PRG
from the mains)
STP
Inhibit frequency inverter
RUN
Enable frequency inverter
Status displays
Display
Meaning
OV
Overvoltage
LV
Undervoltage
IMAX
Set current limit exceeded
TEMP
Heatsink temperature immediately before disconnection ( J
PAR1
Parameter set 1 active, PAR1 flashing: programming is possible
PAR2
Parameter set 2 active, PAR2 flashing: programming is possible
SET
Setpoint input via keypad
Five-digit 7-segment display
Display
Meaning
OFF
Frequency inverter inhibited by a LOW signal at terminal 28
STOP
Frequency inverter inhibited (by STP key or quick stop function or field frequencyf
AS_LC
Autostart lockout, controller will only be enabled after a low-high signal at terminal 28
STO
The parameter is saved
dC_b
DC injection braking active
LU
Undervoltage
SET1
Parameter set 1 is overwritten with the factory setting
SET2
Parameter set 2 is overwritten with the factory setting
rEAd1
Parameter set 1 is overwritten with the operating module data
rEAd2
Parameter set 2 is overwritten with the operating module data
STOE
Parameter sets PAR1 and PAR2 are transmitted to the operating module
l
A
%
H z
L O A D
S T P
P R G
R U N
Bargraph display
The last line of the LCD display shows the inverter load:
g e n e r a t i v e
l o a d
n o
l o a d
l o a d
2 0 %
l o a d
4 0 %
l o a d
6 0 %
l o a d
8 0 %
l o a d
1 0 0 %
o v e r l o a d
1 6 0 %
- 2 -
-10 ° C)
max
MA8201BB 2.0
L O A D
L O A D
L O A D
L O A D
L O A D
L O A D
L O A D
L O A D
= 0Hz)
d