Show/Hide Bookmarks
Change parameters and save
The parameters can be changed when the controller is enabled.
- The parameter sets (C002) can only be overwritten if the controller is inhibited.
Changes of the operating parameters are accepted ONLINE.
Changes affecting the controller initialization must be confirmed with SH + PRG.
without cofirmation
(ONLINE)
A
1. Operating level ¡ [PRG] ¡ Code level
2. [ L ] or [ M ] ¡ Code selection
3. [SH] ¡ Parameter set PAR1 ( ¡ [SH] ¡ Parameter set PAR2)
4.
4. When PAR1 ( PAR2) is flashing: [ L ] or [ M ] ¡ Change parameters
Frequency immediately
operates with the changed
parameter.
5. [SH]
5. [SH] ¡ Code level
Code level
6. [PRG] ¡ Operating level (changed parameter is saved non-volatile)
B
Parameter sets transmitted
You can transmit complete parameter sets to frequency inverters of the same series
(820X ® 820X, 821X ® 821X, 822X/824X®822X/824X) using the operating module.
to the operating module
1. Operating level ¡ [STP] ¡ Controller inhibited
2. Operating level ¡ [PRG] ¡ Code level
3. [ L ] or [ M ] ¡ Select C002
4. [SH] ¡ PAR1 is flashing ¡ [ L ] or
[ M ] ¡ C002 = -6-
[SH] + [PRG] ¡ Display "STO" until transmission is completed ¡ Code level
The parameters of C016, C036, C088, C091, C079 are not transmitted.
5. [PRG] ¡ Operating level (parameter sets saved non-volatile)
6. [RUN] ¡ Controller enabled
l
Parameters
Acceptance and saving
confirmed with SH +
PRG
[SH] + [PRG] ¡ Display "STO" ( approx. 1 s) ¡ Code level
Frequency inverter now
uses the new
parameter.
Transmit parameter sets
to the frequency inverter
[SH] ¡ PAR1 flashing ¡ [ L ] or [ M ] ¡
C002 = -3- ¡ Transmit PAR1 and PAR2
C002 = -4- ¡ Transmit PAR1
C002 = -5- ¡ Transmit PAR2
- 4 -
confirmed with SH + PRG when
controller is inhibited
Operating level ¡ [STP] ¡ controller
inhibited
[RUN] ¡ Controller enabled
Frequency inverter now uses the
changed parameter.
MA8201BB 2.0