3 - Insert the cable in the piping, ease the spotlight in and turn 90º clockwise (Fig. 5).
4 - Put the face plate into place with the logo facing the top of the fixture. (Fig. 5)
C) On flush wall conduits. (Fig. 2c)
Recess required: 15660/15661/Accessories required: 62395/Siphon required: Yes
Procedure:
1 - Place the Ø3.5 O-ring seal on the adaptor.
2- Twist the adaptor into the wall conduit.
3- Insert the cable in the adaptor, ease the spotlight in and turn 90 º clockwise (Fig. 5).
4 - Put the face plate into place with the logo facing the top of the fixture.
D) On a flush wall conduit with G2" thread (Fig. 2d)
Recess required: 15658/15659
Accessories required: 62395/Siphon required: Yes
Procedure:
1 - Screw in the adaptor with a 2" thread into the wall conduit.
2- Insert the cable in the adaptor, ease the spotlight in and turn 90 º clockwise (Fig. 5).
3 - Put the face plate into place with the logo facing the top of the fixture. (Fig. 5)
E) In mini snap-in niche. (Fig. 2e)
Recess required: 15661/Accessories required: No/Siphon required: No.
Procedure:
1- Glue the adaptor (included with the niche) in the niche.
2- Insert the cable in the niche's stuffing box assembly, then tighten the nut on the stuffing box assembly using the special
spanner included with the niche.
3 - Ease the spotlight in and turn 90º clockwise (Fig. 5).
4 - Put the face plate into place with the logo facing the top of the fixture.
For more details about this installation, see the manual for the niche (code 53956).
Liner pools
A) In bushing no. 27084. (Fig. 3a)
Recess required: 27084/Accessories required: No/Siphon required: Yes
Using a diamond tile drill bit, drill a hole 60 mm in diameter into the wall.
Procedure:
1- Screw the adaptor into the bushing.
2 - Insert the cable in the piping, ease the spotlight in and turn 90º clockwise (Fig. 5).
3 - Put face plate into place with the logo facing the top of the fixture. (Fig. 5)
B) In wall conduits. (Fig. 3b)
Recess required: 15664 or 15665 + 06544/Accessories required: No/Siphon required: Yes
Procedure:
1- Screw the adaptor into the bushing.
2 - Insert the cable in the piping, ease the spotlight in and turn 90º clockwise (Fig. 5).
3 - Put the face plate into place with the logo facing the top of the fixture (Fig. 5).
C) In mini snap-in niche. (Fig. 3c)
Recess required: 59983
Accessories required: No/Siphon required: No
Procedure:
1- Screw the adaptor into the niche.
2- Insert the cable in the niche's stuffing box assembly, then tighten the nut on the stuffing box assembly using the special
spanner included with the niche.
3 - Ease the spotlight in and turn 90º clockwise (Fig. 5).
4 - Put the face plate into place with the logo facing the top of the fixture. 5).
For more details about this installation, see the manual for the niche (code 59983).
Polyester pools/spas
A) On bushings 38805 and 53862. (Fig. 3d)
The special products for LumiPlus Mini V3 spotlights fitted in concrete pools should be used (see list on the last page for
product codes).
Recess required: 38805/53862
Accessories required: No/Siphon required: Yes
Using a diamond tile drill bit, drill a hole 60 mm in diameter into the wall.