Electric Heating Toggle; Sauna Heater Safety Clearances - Helo CAVA DET Manuel Produit

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 71
Installation and User Manual HELO CAVA / HELO ROXX DET
Sauna heater insulation resistance:
The sauna heater heating elements may absorb moisture from air, e.g. during storage. This may cause leakage currents. The
moisture will be gone after a few heating sessions. Do not connect the heater power supply through a ground fault interrupter.
However, adhere to the effective electrical safety regulation when installing the sauna heater.

3.5. Electric heating toggle

The electric heating toggle applies to homes with an electric heating system.
Sauna heater has connections (marked 55) for controlling the electric heating toggle. Connector 55 and the heating elements
are simultaneously live (230V).

3.6. Sauna heater safety clearances

NOTE! The thermostat is installed at a distance of 40mm from the ceiling in the middle of the sauna heater.
MIN. mm
Image 4 Safety clearances
Saunaroom
Power
kW
3
m
6,0
5
9,0
9
Table 1 Safety clearances
100
100
10
Safety clearances
min.
H
A
D
3
m
mm
mm
mm
10 1900
100
300
13 1900
100
350
MIN. mm
D
10
Suitable amount
of stones
F
Helo Cava
app. kg
mm
1070
30
1070
30
Suitable amount
of stones
Helo Roxx
app. kg
38
38
11

Publicité

Table des Matières
loading

Table des Matières