en | 8 | Installation and Operating Instructions | Bosch™ EV400 Series Charging Station
Product Features - JP Version
18 mA (nominal; 20mA Max)
Ground Fault
Trip Level
50K ohm Max, 100VAC-Earth
Ground
Assurance
Ground Fault
Automatic before each cycle (Firmware
controlled)
Test
Automatic retries at 15-sec intervals (per
Ground Fault
UL2231-2).
Retry
Manual, 2-minute time-out
Stop Charge
Master Clear
For System Reset (Overrides Ground
Fault Retry and all other fault conditions)
Power
Amber LED
Indication
Charge
Amber (Ready)
Status
Cyan (EV Plugged In)
Indicators
Green/Blue Flashing (Charging)
Red Flashing (Fault) (see tables)
Ratings and
Agency Approvals
Standard Compliances through a National
Agency
Registered Testing Lab (NRTL)
Approvals
Safety: Appendix-4
EMC: Appendix-10 Chapter-5
SAE J1772
REV E | 02.19.2019
Technical Specifications- JP Version
* 200VAC single-phase: L1, L2, and
Voltage and
safety ground.
Wiring
(100V above
ground)
Product Usage
Unit must be properly secured to a vertical
surface and is rated for stationary use only.
The unit may be relocated if mounted in a
similar manner.
Height = 9.0" (229mm)
Dimensions &
Width = 7.3" (185mm)
Weight
Depth = 2.8" (71mm)
Cable Length = 25ft(7.6m) per NEC625
Weight = 12-lbs (5.4kg)
Input Voltage
200VAC and 50/60Hz
Phase AC
Output
30A Max (model dependent - see output
spec. label on side of Power Xpress-2 )
Amperage
Surge
6kV @ 3000A
Protection
Temperature
-40°F to +185°F (-40°C to +85°C)
Storage
Temperature
-31°F to +122°F (-35°C to +50°C)
Operating
Up to 95% non-condensing
Humidity
Enclosure
Rain Proof Type