Product Features - US & EU Versions
Applies to both US and EU
models unless specified
18 mA (nominal; 20mA Max) (US)
Ground Fault
Trip Level
AC I
30 mA (EU)
Δn
50K ohm Max (US), 120VAC-Earth
Ground
Assurance
100K ohm Max (EU), 240VAC-Earth
Automatic before each cycle (Firmware
Ground Fault
controlled)
Test
Ground Fault
Automatic retries at 15-sec intervals (per
Retry
UL2231-2) (US)
EU models - no retry permitted.
Stop Charge
Manual, 2 minute time-out
Master Clear
For System Reset (Overrides Ground
Fault Retry and all other fault conditions)
Power
Amber LED
Indication
Charge
Amber (Ready)
Status
Cyan (EV Plugged In)
Indicators
Green/Blue Flashing (Charging)
Red Flashing (Fault) (see tables)
Ratings and
Agency Approvals
Standard Compliances through a National
Agency
Registered Testing Lab (NRTL)
Approvals
North American (US) Operation
UL 2594 Ed. 2 (2016)
UL 2251
UL 2231-1 & -2 Ed. 2 (2016)
UL1998
SAE J1772
NEC Article 625 (2017)
European Union Operation
IEC 61851-1
IEC 61851-22
IEC 61000-6-3 EMC Emissions
IEC 62196 Coupler Type 2
Installation and Operating Instructions | Bosch™ EV400 Series Charging Station | 7 | en
Technical Specifications- US & EU Versions
Voltage and
Wiring
(120V above
ground)
EU Model
(230V above
ground)
Product Usage
Dimensions &
Weight
Input Voltage
Phase AC
Output
Amperage
Surge
Protection
Temperature
Storage
Temperature
Operating
Humidity
Enclosure
Applies to both US and EU
models unless specified
* 240VAC single-phase (US): L1, L2, and
safety ground.
*208VAC 3-phase, wye-connected (US):
Any 2 phases and safety ground.
* 240VAC 3-phase, delta-connected (US):
with center tap on one leg. Use only the
two phases on either side of the center
tap. The two phases must both measure
120V AC to ground. Do not use the third
leg (208VAC to ground "stinger")
* 230VAC Single-phase (EU):L1, N, PE
(Protective Earth)
Unit must be properly secured to a vertical
surface and is rated for stationary use only.
The unit may be relocated if mounted in a
similar manner.
Height = 9.0" (229mm)
Width = 7.3" (185mm)
Depth = 2.8" (71mm)
Cable Length = 25ft(7.6m) per NEC625
Weight = 12-lbs (5.4kg)
175 VAC – 264 VAC and 50/60Hz
32A Max (model dependent - see output
spec. label on side of Power Xpress-2 )
6kV @ 3000A
-40°F to +185°F (-40°C to +85°C)
-31°F to +122°F (-35°C to +50°C)
Up to 95% non-condensing
NEMA 3R (rain-proof) & per UL 50E
REV E | 02.19.2019