MANUFACTURER IDENTIFICATION DATA

Producting company: EBARA PUMPS EUROPE S.p.A.
Factory address:
Street Torri di Confine, 2/1
36053 Gambellara (VI) ITALIA
Telefono: 0444/706811
Fax: 0444/706950
TELEX:480536
web
www.ebaraeurope.com
1.2

WARRANTY

FAILURE TO COMPLY WITH THE INSTRUCTIONS PROVIDED IN THIS
INSTRUCTIONS HANDBOOK AND/OR ANY SERVICING OF THE ELECTRICAL
PANEL WHICH IS NOT PERFORMED BY OUR SERVICE CENTRES WILL RESULT IN
INVALIDATION OF THE WARRANTY AND WILL RELIEVE THE MANUFACTURER
FROM ANY LIABILITY IN THE EVENT OF PERSONAL INJURIES OR DAMAGE TO
PROPERTY OR THE PANEL ITSELF.
2.

STORAGE

It is good practice to provide proper storage in compliance with the following instructions :
The electrical panel must be stored in a perfectly dry location, away from any heat sources.
The electrical panel must be perfectly sealed and isolated from the external environment, in order to prevent
infiltration of moisture and dust which could disrupt its proper operation.
2.1

PRODUCT DISPOSAL

This symbol on the product indicates that the panel can not be disposed of with household waste.
This provision only concerns the disposal of equipment in the territory of the Union
European (2012/19 / EU).
It is the user's responsibility to dispose of electrical equipment at designated collection points
disposal and recycling of electrical equipment or contact the store where it was
purchased the product.
3.

WARNINGS

Before proceeding with the installation, read these instructions carefully.
The electrical system and connections must be set up by qualified personnel according to the safety regulations
in force in the country where the product is installed, pertaining to the design, installation and maintenance of
technical systems.
Failure to comply with the safety regulations will result in the invalidation of all service coverage under the
warranty.
By qualified personnel we mean those people who, possessing the required training, experience and skills, as
well as knowledge of the pertinent regulations, provisions and prescriptions regarding accident prevention
and operating conditions, have been authorized by the plant safety supervisor to carry out any activity aimed
at preventing safety hazards. (IEC 364 definition for technical personnel)
Make sure that the panel has not suffered any damage during transportation or storage. In particular, make
sure that the external casing is undamaged and in perfect conditions. In the event of long storage (or
replacement of any of the components) all the tests specified by EN standard 60204-1 should be conducted on
the panel.
The SEFC contain electronic devices in case of failure disables the power to the motor but not the tension.
REMOVE TENSION BEFORE MAINTENANCE.
Fluctuations in voltage or power outages can cause the shutdown of the plant independently.
WARNING AT THE POSSIBLE SUDDEN RESTART OF THE PLANT.
DO NOT ISOLATE THE PANEL MORE THAN TWICE IN ONE MINUTE.
ENGLISH
Legal adderss
Street Campo Sportivo,30
38023 CLES (TN) ITALIA
Telefono: 0463/660411
Fax:0463/422782
34