Drive release
• There are four different waiting times for the drive release (see table). These times depend on the actual plasti-
cizing temperature and the set plasticizing temperature. The pre-heating air does not affect the drive release.
• The release zone begins as soon as the actual plasticizing temperature is higher than the set temperature – 20 K.
• Corresponding symbol in the status display:
Drive is not released
Actual plasticizing temperature when the heating is
switched on or when the set plasticizing temperature is
adjusted
Set plasticizing temperature – 5K
< actual plasticizing temperature
Set plasticizing temperature – 20K
< actual plasticizing temperature
< set plasticizing temperature – 5K
Set plasticizing temperature – 20K
> actual plasticizing temperature
(below the release zone)
Set plasticizing temperature – 20K
> actual plasticizing temperature
(below the release zone)
• If the WELDPLAST S1 cannot keep the actual plasticizing temperature in the release zone for more than 10
seconds when the drive is released, it will be locked again. As soon as the device reaches the release zone again
and the time defined in the table has elapsed, the drive is released again.
Key lock
• Press and hold the «Up»
activate or deactivate the key lock.
Power supply interruption
Drive state before power supply
interruption
Drive released
Welding working display
Drive released
(pre-heating air > 100°C)
Drive released
(pre-heating air < 100°C)
and «Down» keys (21/22)
Duration of power
supply interruption
≤ 5 sec
> 5 sec
> 5 sec
Drive released
Set plasticizing
temperature
> 190°C
< 195°C
at the same time for at least two seconds to
WELDPLAST S1 state after power supply
interruption
The device starts up without restart protection
and switches straight to the state it was in before
the power supply was interrupted
The device switches straight to «Cool down
mode»
The device starts up and the start display appears
on the display (5).
Release time once
the release zone is
reached
Drive is released
immediately
30 sec.
2 min. 30 sec.
3 min. 30 sec.
33