3.3.7 – Electrical connections to the GD0N control unit
1 Open the cover by undoing bolt [A] (Fig. 38) and pressing button [B]
(Fig. 39).
38
A
2 Remove the circular part [C] with a screwdriver, as in fig. 40.
40
42
FL100
16 – English
39
B
C
TX
3 Cut the rubber membrane [D] (Fig. 41) so as to route the cable through
it and fit it in hole [C] (Fig. 40).
41
D
4 Use Fig. 42 and the connection description in Table 6 as reference.
• if using the PH00 photocells, remove the small piece of wire between
terminals 3 and 7 and make the connections as in Fig. 42.
• if using the flashing light aerial, remove the piece of wire, which is con-
nected to terminal 2, and connect the RG58 type shielded cable.
5 When the connections have been completed, secure the cables using
suitable clamps.
6 To close the cover, turn and push until a click is heard. Tighten down
screw [A].