MAX/MIN
When the "MAX/MIN" button
the Maximum, Minimum and Average values as the meter continues
to take samples.
1. When measuring, press "MAX/MIN" button
the Maximum value (MAX), Minimum value (MIN) and Average
value (AVG). If a new Maximum, Minimum or Average occurs, the
display will update with the new value.
2. Press "MAX/MIN" button
normal measuring mode.
RELATIVE MODE
When the REL/LPF button
relative value on the main display and real time measurement on the
secondary display. Press the REL/LPF button
measuring mode.
LOW-PASS FREQUENCY MODE
For voltage readings of high frequency motors, long press the REL/
LPF button
11
accurate reading. Long press the REL/LPF button
normal measuring mode.
NON-CONTACT VOLTAGE TESTING
Approach the conductor under test leading with the non-contact
voltage sensor
when AC voltage is detected by the non-contact voltage sensor.
CONNECTING TEST LEADS
Do not test if leads are improperly seated. Results could cause
intermittent display readings. To ensure proper connection, firmly
press leads into the input jack completely.
8
FUNCTION BUTTONS
8
11
and meter will apply a low pass filter to ensure a more
. The meter delivers visual warning signals
16
OPERATING INSTRUCTIONS
INCORRECT
CORRECT
is pressed, the meter keeps track of
8
for more than one second to return to
is pressed, the meter will show the
to toggle between
8
to return to normal
11
to return to
11
15

Publicité

Table des Matières
loading

Table des Matières