6.3 Electrical connection

WARNING OF ELECTRICAL ENERGY!
RISK OF FATAL INJURY!
Live components have been installed near
this symbol. Covers bearing this sign may
only be removed by a certifi ed skilled electri-
cian.
The electrical connection must be carried out by a
qualifi ed electrician who is authorised to carry out such
work!
Statutory regulations and the connection specifi cations
issued by the local power supply company must be
strictly observed.
When connecting the appliance it must be ensured that
there is a device which makes it possible to universally
disconnect it from the mains with a contact opening
width of at least 3mm. Line-protecting switches, fuses
or contactors are suitable cut-out devices. When
connecting and repairing the appliance disconnect it
from the electricity supply with one of these devices.
The earth wire must be suffi ciently long so that if the
strain relief fails, the live wires of the connecting cable
are subjected to tension before the earth wire.
Any superfl uous cable must be removed from the ins-
tallation area beneath the appliance.
Make sure that the local mains voltage is the same as
the voltage on the rating label.
The hob has been fi tted with a temperature-resistant
connection cable in the factory.
The connection cable must be at least H05 RR-F.
If the excess cable of this appliance is damaged, it has
to be replaced by the manufacturer, the Customer Ser-
vice of the manufacturer or by another qualifi ed person
to avoid danger.
Full protection against accidental contact must be en-
sured on installation.
Attention: Incorrect connection may result in the
power electronics unit being destroyed.
Power supply
Mains voltage: 220 - 240V~, 50/60 Hz
Component rated voltage: 220 - 240V

6.4 Technical data

Hob dimensions
height/ width/ depth ...mm
Cooking zones
rear . . . . . Ø cm/ kW
front . . . . Ø cm/ kW
Hob ............................ kW
28
Instructions for assembly
47 x 300 x 520
18 (1.8)
14.5 (1.2)
3.0

6.5 Initial operation

Once the hob has been installed and the power supply has
been provided (mains connected) an automatic test of the
controls will be carried out and information for Customer
Service will be indicated.
Important: No items may be on the touch control sensor
keys when the appliance is being connected!
Briefl y wipe over the surface of the hob with a sponge and
soapy water and then dry with a clean cloth.
Important:
Subsequent to connection to the mains or after a power
cut, the lock function is activated (see chapter Lock/ child
safety device).
Calibration
Pressing locking key,
Calibration of the electronic is carried out. It is important
that the operation of the lock button is done without gloves
with clean fi ngers and slight pressure.