Battery Backup Assembly Instructions

Replace the power transformer batteries every six months and
NOTICE:
after each power failure use. Under normal conditions, the battery
backup will operate the chair two times, but this performance
cannot be guaranteed.
The performance of the built-in battery backup cannot be guaranteed. If you require continuing
use during a power outage, you should purchase a separate battery backup system. Contact
your La-Z-Boy
®
dealer for more information.
To reduce battery consumption, the massage and heat features are blocked and unavailable
when the battery backup is in use. Additionally, the operating speed is reduced to decrease
energy consumption.
Always maintain constant even pressure on the button when operating on battery backup to
reduce the energy consumption.
The battery backup is located in the power transformer and uses two 9-volt alkaline
batteries (not included).
1. Unplug the 120 volt power cord from the electrical outlet, and disconnect the power
transformer connector from the power supply connector.
2. The battery compartment is located in the bottom of the power transformer. Slide the battery
cover(s) over to access the battery compartment(s). Your power transformer will look like
F
1 or F
2.
IGURE
IGURE
3. Snap the connection caps on the battery terminals. Place the batteries in the power transformer.
4. Slide the battery cover(s) over the batteries.
5. Proceed to the Operating Instructions.
F
1
IGURE
Power
(2) 9-Volt
Battery
Transformer
Alkaline Batteries
Cover
PowerReclineXR
& PowerReclineXRw
®
Transformer Specifications:
Input: 100V-240V~, AC 50/60Hz
Output: 29V, DC 2A
18
Note: Transformers vary by style and date of manufacturer.
(2) 9-Volt
F
2
IGURE
Alkaline Batteries
Power
(2) 9-Volt
Battery
Transformer
Alkaline Batteries
Cover
PowerReclineXR
®
Transformer Specifications:
Input: 100V-240V~, AC 50/60Hz
Output: 29V DC 1.5A