3.11.1 Positioning of the oil bottle

To carry out this operation, it is necessary to use the oil filling kit (1 needle,
1 transparent pipe, 1 pipe connection and 1 spout for the oil bottle). This kit
is NOT supplied.
-
Remove the pump cap and insert the fittings.
-
Attach the spout to a new bottle of hydraulic oil and connect the hose
to the fittings and the bottle spout.
- Turn the bottle upside down and pierce it with the pin, as shown in the
picture, to ease the oil passage towards the pump. Fill the pump until
no air bubbles are visible in the hose.
WARNING
While replacing the oil bottle, during the filling process, close all the bleed
valves of the cylinder/s. To bleed the system, check that oil is always present
in the filling hose. If some air is in the system during the bleeding process,
the whole bleeding process must be started again.
CAUTION
Replace the bottle before it empties and use recovered oil only after 24 hours.

3.11.2 Purging procedure

NOTICE
Carry out the purging procedure as indicated in the installation and maintenance manual of the cylinder
used. Then check that the oil level is suitable by turning 1/2 turn the steering wheel and by making the
oil come out of the bleed valve. Close the valve and check the system.

3.12 General recommendation

WARNING
It is very important to check the absence of air in the system before using the boat! We recommend
trying to manually move the engine/s or the helm/s towards port and starboard, making sure that there
is no movement of the cylinder body on the main cylinder shaft.
If the cylinder body moves too much, there is still air in the system. The air presence in the system can
cause bad responses to the controls and so it can cause damage, injuries or death.
WARNING
Check the system response by moving the pump.
DANGER
After 24 hours repeat the purging and make sure there are no leaks.