Ultraflex UP25 F Manuel D'installation Et D'entretien page 16

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ULTRAFLEX
4
By using the proper template supplied with
this manual, make the holes (4) required by
the installation in the suitable position on the
dashboard.
5 Position the pump (2) on the dashboard front
side (5) interposing the gasket (6) and fix it by
inserting the 4 washers (7) and by tightening
the 4 self-locking nuts (8) with a 10 mm wrench
and a torque of 10 Nm (7,4 lb ft).
CAUTION
If the self-locking nuts are disassembled (8), they
must be replaced. (Contact our assistance
service, see page 6).
WARNING
Install the pump by positioning the filling hole
(9) towards the top (see the picture) for the right
pump operation and to allow filling and purging
the system completely (see par. 3.11).
6
Position the steering wheel supplied
separately (10) on the pump shaft (11) by using
the suitable key (12). Insert the washer (13) and
tighten the self-locking nut (14) with a 19 mm open
end wrench and with a torque of 40 Nm (29,5 lb ft);
then grease the thread by using some anti-seize
®
grease MOLYKOTE
CAUTION
If the self-locking nut (14) is disassembled, it must
be replaced. (Contact our assistance service, see
page 6).
page 16
of 101 -
PUMP FOR HYDRAULIC SYSTEMS
1000 or a similar one.
Installation and maintenance manual
4
5
9
2
12
10
13
14
8
7
8
7
8
7
8
7
6
11

Publicité

Table des Matières
loading

Table des Matières