Danfoss VLT HVAC Basic Drive FC 101 Manuel De Configuration page 74

Masquer les pouces Voir aussi pour VLT HVAC Basic Drive FC 101:
Table des Matières

Publicité

Programmation
6
6
Illustration 6.4 Assistant de configuration de la boucle ouverte
72
VLT
At power up the user is
asked to choose the
prefered laguage.
Select language
[1] English
Setup 1
Status
Quick
Main
Menu
1
Menu
Menu
Com.
OK
On
Warn.
Alarm
O
Auto
Hand
Reset
On
On
Power Up Screen
OK
The next screen will be
the Wizard screen.
Press OK to start Wizard
Press Back to skip it
Setup 1
Main
Status
Quick
if
OK
Menu
Menu
Menu
2
Com.
OK
On
Warn.
Alarm
O
Hand
Auto
Reset
On
On
Wizard Screen
if
0.0 Hz
0.0 kW
Setup 1
3
Status
Quick
Main
Menu
Menu
Menu
Com.
OK
On
Warn.
Alarm
O
Auto
Hand
Reset
On
On
Status Screen
The Wizard can always be
reentered via the Quick Menu!
(Do not AMA)
Auto Motor Adapt OK
Wizard completed
Press OK
Press OK to accept
37
38
Setup 1
Setup 1
0.0 Hz
39
0.0 kW
Setup 1
®
HVAC Basic Drive FC 101 Manuel de configuration
... the HVAC FC 101 Wizard starts
Select Regional Settings
[0]
Power kW/50 Hz
Setup 1
Grid Type
[0]
200-240V/50Hz/Delta
Setup 1
Select Motor Type
Asynchronous
[0]
PM motor
Setup 1
Set Motor current
12
3.8
A
Setup 1
Select Motor nominal speed
3000
RPM
13
Setup 1
Set Motor Cont. Rated Torque
14
5.4
Nm
Setup 1
Stator resistance
15
0.65
Ohms
Setup 1
Motor poles
16
8
Setup 1
Back EMF at 1000 rpm
17
57
V
Setup 1
d-axis inductance
18
5
mH
Setup 1
Set Max Output Frequency
19
0065
Hz
Setup 1
Set Motor Speed low Limit
0000
Hz
20
Setup 1
Set Motor Speed high Limit
21
0050
Hz
Setup 1
Set Ramp 1 ramp-up time
22
0003
s
Setup 1
Set Ramp 1 ramp-down Time
0003
s
23
Setup 1
Motor Type = PM Motor
Select T53 Mode
25
Current
[0]
Current
Setup 1
Set T53 Low Current
04.66
A
28
Setup 1
Set T53 High Current
13.30
A
29
Setup 1
Set Min Reference
0000
Hz
30
Setup 1
Set Max Reference
31
0050
Hz
Setup 1
Select Function of Relay 1
[0] No function
[0]
32
Setup 1
Select Function of Relay 2
33
[0]
No function
Setup 1
Automatic Motor Adaption
34
[0]
O
Setup 1
Do AMA
AMA running
35
-----
Setup 1
AMA OK
MG18C504 - Rév. 2014-01-14
4
5
6
Asynchronous Motor
Set Motor Power
1.50
kW
7
Setup 1
Set Motor Voltage
0050
V
8
Setup 1
Set Motor frequency
9
0050
Hz
Setup 1
Set Motor current
10
04.66
A
Setup 1
Set Motor nominal speed
11
1420
RPM
Setup 1
Motor Type = Asynchronous
Active Flying start?
[0]
24
Disable
Setup 1
Voltage
Set T53 low Voltage
0050
V
26
Setup 1
Set T53 high Voltage
0220
V
27
Setup 1
AMA Failed
36
AMA failed

Publicité

Table des Matières
loading

Table des Matières