5.4 Troubleshooting

Auto alignment
procedure fails
If the auto alignment procedure fails it is indicated as follows:
Behaviour on the auto target:
The red left and right LEDs on the auto target are flashing and
The green ON/OFF LED lights up until you press the green ON/OFF key
. Otherwise the auto target switches off automatically after 10 min.
Behaviour on the Zeta125s:
The main beam of the Zeta125s moves back to the starting position
and is flashing.
The display of the Zeta125s shows this symbol:
If the auto alignment procedure fails it can have the following reasons
a) There was not permanently free sight between Zeta125s and the auto
target, for example a person moves through the beam during the auto
alignment procedure.
b) The alignment of the Zeta125s was not in the +/-3° or +/-6° area of
the auto alignment modes.
Auto Target
Zeta125/ Zeta125s | 63