Before you
call for service
40
Problem
Possible Cause
Convection Fan Not
The convection fan (depending on the function you are using) may cycle on and
On All The Time
off until the function is over or the door is opened for optimized performance.
This is normal. In addition, the convection fan may cycle in the clockwise and
counter clockwise direction until the function is over or the door is opened.
Burners Do Not
Electrical plug is not plugged into a live power outlet.
Light Or Spark
Gas supply not turned on.
Randomly
Burner parts not replaced correctly.
Holes in the simmer rings or slits in the burner rings are clogged.
Clogged orifice, or wet burners or electrodes.
Cooktop Lockout feature is activated.
A fuse in your home may be blown or circuit breaker tripped.
Burners Have
Burner parts not replaced correctly.
Yellow Or Yellow-
Tipped Flames
A. Yellow flames: Call
for service.
If burner flames look like (A), call for service. Normal burner flames should look
like (B) or (C), depending on the type of gas.
Burner Flames Very
The range may be connected to the wrong fuel type. Contact the person who
Large Or Yellow
installed your range or made the conversion
Burner Control
When the knob is at the OFF position, it must be pushed in before it can be turned,
Knob Will Not Turn
and it can only be turned in a counterclockwise direction. When the knob is at any
other position, it can be turned in either direction without being pushed inwards.
Condensation Or
Condensation or fogging on the inside of the oven door glass is normal
Fogging On The
during the preheating of the oven and will evaporate usually by the end of the
Inner Door Glass
preheating cycle.
Burner Flames
Airborne dust; cool-mist humidifier; debris on or inside burner.
contain Flickers of
Orange
Troubleshooting Tips
Professional All-Gas Range
B. Yellow tips on outer
cones: Normal for
propane (LP) gas.
C. Soft blue flames:
Normal for natural gas.