Wall Outlet; Roof Outlet - WANDERS Stealth Mode D'emploi Et Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Gastype
A (min.-max.)
Nat. gas
1,0 - 3,0 m
LPG
1,5 - 3,0 m
all dimensions are exclusive the length of the wall outlet
B
Gastype
B (min. -
A1 (min. -
max.)
max.)
Nat. gas
1 - 3 m
1 - 10 m
LPG
1,5 - 3 m
1 - 10 m
(A1 + A2 : B) : 1
Proportion vertical: horizontal (or 45
is always at least 2 : 1
all dimensions are exclusive the length of the roof outlet

Wall outlet

Always allow one metre vertical before passing through the outer wall.
The maximum length of the horizontal placed pipes is 3 meters.
Determine the location of the gas unit and the exterior wall duct.
Make an opening of Ø 155 mm for the wall duct.
Connect the wall duct with a curve to the mouth of the appliance. Push them fi rmly together and place
the clip bindings. The blue rubber ring ensures suffi cient sealing of the discharge system of the waste gas.
If the appliance is placed more than 1 metre from the wall, place the vertical one-metre pipe fi rst on the
appliance, then place the curved part, then the exterior wall duct, and then make them gastight.

Roof outlet

You can place the outfl ow anywhere on the roof, if necessary with a bend to the ridge of the roof. The roof
duct is supplied with a universally adjustable roof tile for a tilted roof, or with an adhesive plate for a fl at roof.
Determine the location of the gas unit and the outfl ow to the roof.
B
B (min. - max.)
Collar shaft
0 - 3,0 m
NO
0 - 3,0 m
NO
A1 + A2
Collar
(min. - max.)
shaft
1 - 10 m
NO
1 - 10 m
NO
up)
o
Gastype
A (min. - max)
Nat. gas
1,0 - 10,0 m
LPG
1,5 - 10,0 m
all dimensions are exclusive the length of the roof outlet
Collar shaft
from 3,0 m
Ø 50 mm
from 3,0 m
Ø 50 mm
25

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Black stealth

Table des Matières