External air intake vent (fi gs. C-D-E-
External air intake vent (fi gs. C-D-E-
F-G)
F-G)
Connection with the external environ-
Connection with the external environ-
ment, with a section of 300 cm², is
ment, with a section of 300 cm², is
absolutely necessary for the fi replace to
absolutely necessary for the fi replace to
function effi ciently:
function effi ciently:
it is therefore essential to ensure this
it is therefore essential to ensure this
intake capacity.
intake capacity.
The said connection must directly link
the air regulation mechanism (10 - fi g.
D) with the external environment.
The mechanism, delivered separately,
may be fi tted at either the left or right of
the fi replace.
For fi tting proceed as follows:
- Remove the cover (A - fi g. C) fi xed
with screws and apply the regulation
mechanism using the same screws.
- Hook on the fl exible connection pipe,
which may be in fl exible aluminium.
- Take care to seal the points where air
dispersion could occur.
It is advisable to apply to the outer part
of the air intake vent a protective grill,
which must not reduce the air fl ow ca-
pacity, however.
For lengths of more than 3 m or in the
case of bends, increase the indicated sec-
tion by 10% to 20%.
The external air must be taken in at fl oor
level (it must not be taken in from a
higher position).
In positioning the control wire of the
In positioning the control wire of the
external air gate, take care that it does
external air gate, take care that it does
not come into contact with the hot
not come into contact with the hot
parts of the fi replace, since this would
parts of the fi replace, since this would
damage the plastic coating.