control function i:
Connect the control medium to the pilot air port 1 and 2 of the
actuator (see "Fig. 18: Pneumatic connection")
Pressure on connection 1 opens the valve.
Pressure on connection 2 closes the valve.
Air discharge connection
CFA, CFB
Pilot air port CFI
Pilot air port
CFA, CFB, CFI
Fig. 18:
Pneumatic connection
control air hose:
6/4 mm or 1/4" control air hoses can be used.
Optionally a pilot air port is possible via a G 1/8 thread.
Type 2101
Installation
2
1
8.5

removal

DanGer!
risk of injury from discharge of medium and pressure!
It is dangerous to remove a device which is under pressure due to
the sudden release of pressure or discharge of medium.
▶ Before removing a device, switch off the pressure and vent the
lines.
procedure:
Loosen the pneumatic connection.
Remove the device.