Service

GENERAL

All maintenance activities must happen at an disconnected machine and hoses
without pressure. Checking the electric components can happen exclusively by
an expert. Exclusively accessories and replacement components which have
been approved by the manufacturer can be used. Directly after the activities all
securities- and protection parts must be assembled, before the machine is put
in functioning. "a golden rule" that contributes to a perfectly working machine
with few problems, is well the following:
A daily control and cleaning of the machine frequently do wonders!
To be able to guarantee a perfectly working system, one has first necessary a
reliable and technical well considered machine, which is then faced secondly
at regular times with a thorough maintenance. Therefore the experience and
the "know-how" of DiBO a technical good working machine is insured and
large maintenance turns can be carried out by experienced DiBO technicians
by means of appointment or maintenance contract, we can suppose in advance
that it is satisfied to these two points.
MAINTENANCE DIAGRAM
1
General
The user can carry out only those actions for which in this book authorisation
are given. Each other act has been prohibited!
2

Periodic maintenance

DISCRIPTION
Control of the electric cables, high and low pressure
hoses and couplings and control of oil level.
Refreshing pump oil.
Cleaning water filter.
All following refreshments of pump oil.
Extra control/replacement of joints, valves, o- rings
by acknowledged DiBO- technicians!
3

Control of oil level / refreshing of pump oil

Check for each use of the machine the oil by way off oil level glass or with the
oil level bar. Oil must stand right with the sign of the oil level bar, if the this case
is not, fill the oil until the middle of the look glass. If oil looks forward to there
milky, consult directly the DiBO technicians. To refresh oil, as follows work goes:
• Unbolt the drain plug below the pump.
• Unbolt the tap with the oil level bar.
• Catch all oil in a barge and remove oil.
• Force up the drain plug there and top up the oil in the breach to the upper
part to the right level.
• Force up the tap with the oil level bar there.
• Recommended oil: 1.836.041.
4

Control of oil level/refreshing of pneumatic valve

Check the oil level regularly by means of the look glass at the top. Oil has no
lubrication function (=static function), therefore there is no wear possible! Fill up
is only needed when the oil level has been decreased! Check the oil by way off
oil level glass or with the oil level bar. Oil must stand in the middle of the sign of
oil level bar, if this is not the case, fill the oil until the middle of the look glass. If
oil looks forward to there milky, consult directly the DiBO technicians. To refresh
oil, as follows work goes:
• Unbolt the tap at the top with oil level bar.
• Top up the oil to the upper side, to to the middle of oil level and force up the
tap there.
• Recommended oil: 1,836,025 (+ - 0.6 litres hydraulic oil).
DiBO 21
E N
S E R V I C E    
PERIOD
After each use.
First 50 hours.
Each 50 hours.
Each 200 hours.
Each 600 hours.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1.780.494