Cleaning The Heat Sink; Replacing The Fan - Kaco blueplanet 50.0 TL3 M1 WM OD IIGS Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 59
1 Use a vacuum cleaner or a soft brush to remove dust from the fan cover and from the top of the device on a regular
basis.
2 Remove dust from the ventilation inlets if necessary.
8.2.2

Cleaning the heat sink

NOTE
Refer to our service and guarantee conditions on our homepage.
ü The cleaning intervals must be adapted to match the ambient conditions of the installation location.
In sandy environments, we recommend cleaning the heat sinks and fans every quarter.
8.3

Replacing the fan

Dismounting the fan
↻ Lack of current and voltage ensured on the inverter.
1 Wait until both fans are no longer turning.
2 Detach the fastening for the fan safety grille [ T_20 & W_7].
3 Detach the fastening for the fan and carefully remove the fan downwards [
T_20 & W_7].
4 Carefully disconnect the plug connector for the dismounted fan from inside the
housing.
5 Remove the fan from the base plate.
» Install the replacement fan.
Page 26
5
4
3
Fig. 24: Dismounting the fan
Fig. 25: Unplug the fan plug
1
Fan
2
Protective grating for fan
3
Fastening for protective grat-
ing
4
Fastening for fan
5
Base plate
6
Connector plug
7
Connection socket
KACO blueplanet 50.0 TL3
1
2
6
7

Publicité