Installation
MOUNTING THE SAFETY REVERSING SENSORS
1.
Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor.
2.
Use wing nuts to fasten safety reversing sensors to brackets, with lenses pointing
toward each other across the door. Be sure the lens is not obstructed by a bracket
extension.
3.
Finger tighten the wing nuts.
Wing Nut
WIRE THE SAFETY REVERSING SENSORS
1.
Run the wire from both sensors to the door operator. Attach the wire to the wall and
ceiling with the staples.
2.
Strip 7/16" (11 mm) of insulation from each set of wires. Separate the wires. Twist
the white wires together. Twist the white/black (or all black) wires together.
3.
Insert the white wires into the white terminal on the door operator. Insert the white/
black wires into the grey terminal on the door operator. To insert or remove the
wires from the terminal, push in the tab with a screwdriver tip.
7/16"
(11 mm)
WHT
WHT/BLK
(or all black)
Bell wire
Carriage Bolt
15
HARDWARE
Carriage Bolt
1/4"-20x1/2" (2)
Wing Nut
1/4"-20 (2)