Indications for use
The Surgic Pro + / Surgic Pro is intended for use in dental oral surgery and dental implant.
The main unit is designed to be used with a specific dental micromotor that drives dental handpieces fitted with appropriate tools to cut hard
tissues in the mouth.
Cautions for handling and operation
Read these safety cautions thoroughly before use and operate the product properly.
These indicators are to allow you to use the product safely, prevent danger and harm to you and others. These are classified by degree of danger, damage and seriousness. All indicators concern safety, be sure to follow them.
Classification
CAUTION
Explains an instruction where minor to medium injury or physical damage may occur.
1. Safety precautions prior to use
CAUTION
• This Micromotor is used only for the NSK Surgic Pro series. Do not connect this Micromotor to other
Control Units.
• Do not attempt to disassemble the product nor temper with the mechanism.
• Do not disconnect the Motor Cord from the motor.
2. Package Contents
No.
Description
1 Optic Motor / Non-Optic Motor (With Motor Cord)*
2 Protection Plug
3 O-ring (Protection Plug)
4 O-ring (Motor)
*Either Motor is included.
3. Installation
Align the [ ] mark on the Motor Cord with [ ] mark on the Control
Unit.
Push the Base of Motor Cord Plug into the socket until the locking
joint 'clicks' into place.
To disconnect the plug; pull back the Lock Joint, pull further to
disconnect the cord.
4. Maintenance (Cleaning) and Sterilization
Refer to the operation manual for Surgic Pro series.
5. Specification
Model
SGL70M
Type
E1023
Rotation Speed Range
200 – 40,000 min
-1
Input Voltage
DC24V
Dimensions
Ø23.5xL103.3mm (without cord)
Cord Length
2m
Optic
White LED
Weight
Approx.280g
Temperature
Use Environment
Between 0-40°C (32-104°F)
Transportation and
Between -10-50°C (14-122°F)
Store Environment
No moisture condensation in the motor. Use at outside of these limits may cause malfunction.
Degree of Danger or Damage and Seriousness
Quantity
1
1
2
2
Lock Joint
[ ● ] mark
SG70M
E1025
-
Humidity
Atmospheric pressure
Between 10-85% RH
Between 700-1060 hPa
Between 10-85% RH
Between 500-1060 hPa
SGL70M/SG70M
Classification of equipment
• Method of sterilization or disinfection recommended by the manufacturer :
-Refer to the operation manual for Surgic Pro series.
• Do not drop, hit, or subject to excessive shock.
• Do not wipe or clean with high acid water. Do not immerse in any solutions.
• This product is delivered in a non-sterile condition and must be autoclaved prior to use.
• U.S. Federal law restricts this device to sale by or on the order of a licensed physician.
6. Disposing Product
Consult with your dealer from whom you purchased the device regarding waste disposal.
7. Symbols
The EU directive 93/42/EEC was applied in the design and production of this medical device.
Caution, See Operation Manual
Caution: U.S. Federal law restricts this device to sale by or on the order of a licensed physician
Manufacturer
This product can be sterilized in a steam sterilizer up to Max. 135°C.
The surface of the product can be used with a Thermo-Disinfector prior to Sterilization.
GS1 DataMatrix for Unique Device Identifier.
8. Warranty
Fig. 1
NSK products are warranted against manufacturing errors and defects in materials. NSK reserves the right to analyze and determine the
cause of any problem. Warranty is voided should the product be not used correctly or for the intended purpose or has been tampered
with by unqualified personnel or has had non NSK parts installed. Replacement parts are available for seven years beyond discontinuation
of the model.
Micromotor
OM-E0820E 000
ENGLISH
2018.07.17 002
S

Publicité

loading

Sommaire des Matières pour NSK SGL70M

  • Page 1 8. Warranty Fig. 1 NSK products are warranted against manufacturing errors and defects in materials. NSK reserves the right to analyze and determine the 4. Maintenance (Cleaning) and Sterilization cause of any problem. Warranty is voided should the product be not used correctly or for the intended purpose or has been tampered Refer to the operation manual for Surgic Pro series.