ALARM
AL_41: Function
AL_42: Function
AL_44: Function
AL_45: Function
AL_46: Function
AL_47: Function
AL_48: Function
AL_49: Function
AL_50: Function
AL_52: Function
AL_54: Function
AL_55: Function
AL_57: Function
AL_59: Function
AL_61: Function
MEANING
Overheating
Power damaged
Relay fault
Relay fault dc
Over-current
Brushes
Over-current
Suction device
Over-current
Water pump
Current measurement
Brush 1 and 2
Current measurement
Suction device 1
Function
Connections
Brush 1 and 2
Connections
Suction device 1
Unbalance
Current measurement
Brush actuator
ENGLISH - 21
SOLUTION
Turn off and wait for the machine to cool down.
Check the consumption of the brush and suction
device motors, the status of the ambient ventila-
tion and restart.
Turn off the machine for at least 10 seconds, then
restart.
The Relay/Remote switch does not close.
Check the remote switch operation.
In case of relay on board, if persists replace the
board.
Detection of Relay/Remote switch closed at start.
Check the status of the remote switch contacts.
In case of relay on board, if persists replace the
board.
Turn off the machine, check the load (motor),
the mechanics, the cabling and the connections,
then look for the presence of a short circuit on the
outlet, than restart.
Turn off the machine, check the load (motor),
the mechanics, the cabling and the connections,
then look for the presence of a short circuit on the
outlet, than restart.
Turn off the machine, check the load (motor),
the mechanics, the cabling and the connections,
then look for the presence of a short circuit on the
outlet, than restart.
Check the consumption and the kind of ap-
plication of the brush function, then restart the
machine.
Check the consumption and the suction device
function, then restart the machine.
Check the brush motors connection.
Check the suction device motor connection.
Check the consumption of the brush motors.
Check the consumption of the actuator motor and
the status of the mechanical moving parts.