The machine does not deliver any
current and the thermal overload
indicator lamp lights up.
The display is on but the device
does not deliver any current.
If, when the unit is on and you
put your hand on the welding
unit's body, you feel tingling
sensation.
The display is on but the device
does not deliver any current.
When starting up, the display
indicates
.
Instable arc
The
tungsten
oxidised and tern at the end of
welding.
The electrode melts
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported
26
GOLD MULTI 210-2 / 210-4 XL / 211-4
The welder thermal protection has
turned on.
The cable of the earth clamp or
electrode holder is not connected to
the welder.
The welding unit is not correctly
connected to the earth.
The cable of the earth clamp or
electrode holder is not connected to
the welder.
The input voltage is outside of
the range (230V + 15% for single
phase or 400V + 15% for 3-phase).
Default coming from the tungsten
electrode
Too important gas flow rate
Welding zone
electrode
gets
Default coming from post-gas or the
gas has been stopped prematurely.
Polarity error
Wait for the end of the cooling time, around 2
minutes. The indicator lamp turns off.
Check the connections.
Check the plug and the earth of your electrical
network.
Check the connections.
Have the electrical installation checked.
Use a tungsten electrode with the adequate size
Use a well prepared tungsten electrode
Reduce gas flow rate
Protect welding zone against air flows
Check and tighten all gas connections. Wait until
the electrode cools down before stopping the gas.
Check that the earth clamp is really connected to +
EN