Données Circuits De Puissance Et De Commande - GE ASTATplus Manuel D'utilisation

Table des Matières

Publicité

5.2. Données circuits de puissance et de commande
Selon CEI Classe 10
No. Art.
In
Total
Fusibl. Fusibles
pertes
aM
100% In
(F1)
A
W
A
QC _ F DP 17
67
25
QC _ G DP 21
78
32
QC _ H DP 27
88
40
QC _ I DP 38
116
63
QC _ J DP 58
208
80
QC _ K DP 75
277
100
QC _ L DP 86
302
125
QC _ M DP 126
389
200
QC _ N DP 187
719
250
QC _ Q DP 288
1097
400
QC _ R DP 378
1286
500
QC _ S DP 444
1374
630
QC _ T DP 570
2086
800
QC _ U DP 732
2352
1000
QC _ V DP 1020 3000
1250
QC _ X DP 1290 3839
2x800 S3üf02/110/1000A/690V –
Selon CEI Classe 20
QC _ F DP 14
56
20
QC _ G DP 17
65
25
QC _ H DP 22
74
32
QC _ I DP 32
99
63
QC _ J DP 48
178
80
QC _ K DP 63
236
80
QC _ L DP 72
257
100
QC _ M DP 105
325
160
QC _ N DP 156
591
200
QC _ Q DP 240
901
315
QC _ R DP 315
1063
400
QC _ S DP 370
1136
500
QC _ T DP 475
1721
630
QC _ U DP 610
1950
800
QC _ V DP 850
2491
1000
QC _ X DP 1075 3168
1250
(1) Les 3 contacts de DC3 doivent être branchés en parallèle
Protection circuit dérivé, UL
Gould-Shawmut, Fusibles semi-conducteurs
No. Art.
Type
Type
A50QS (3)
A50P (4)
QC _ F DP
50A
-
QC _ G DP 60A
-
QC _ H DP 80A
-
QC _ I DP
100A
-
QC _ J DP
150A
-
QC _ K DP 200A
-
QC _ L DP
225A
-
QC _ M DP 350A
-
QC _ N DP 450A
-
QC _ Q DP 600A
-
QC _ R DP 2X500A en parallèle -
QC _ S DP
2x600A en parallèle -
QC _ T DP
-
2x1000A en parallèle -
QC _ U DP -
2x1200A en parallèle -
QC _ V DP
-
2x1600A en parallèle -
Remarque: Lorsque des démarreurs ASTATplus sont utilisés en combinaison avec des fusibles semi-conducteurs, la coordination type 2 selon
CEI 947-4 est realisée. Ces fusibles sont recommandés pour une meilleure protection générale contre les court-circuits. Le fusible semi-
conducteur spécifié peut assurer une protection des circuits dérivés. Consulter les codes électriques locaux applicables.
Fusibles
Jean Müller
BUSSMANN type
type
(Typower Sicu 660V~
conception mech.)
S00C+/üf01/40A/690V
00
S00C+/üf01/50A/690V
00
S00C+/üf01/80A/690V
00
S1üf01/110/100A/690V
00
S1üf01/110/125A/690V
00
S1üf01/110/160A/660V
00
S1üf01/110/200A/690V
00
S1üf01/110/250A/690V
00
M2üf02/315A/690V
00
M3üf02/500A/690V
2
S3üf02/110/630A/690V
2
S3üf02/110/800A/690V
2
S3üf02/110/1000A/690V 3
S3üf02/110/1250A/690V 3
S3üf02/110/800A/690V
S00C+/üf01/40A/690V
00
S00C+/üf01/50A/690V
00
S00C+/üf01/80A/690V
00
S1üf01/110/100A/690V
00
S1üf01/110/125A/690V
00
S1üf01/110/160A/660V
00
S1üf01/110/200A/690V
00
S1üf01/110/250A/690V
00
M2üf02/315A/690V
00
M3üf02/500A/690V
2
S3üf02/110/630A/690V
2
S3üf02/110/800A/690V
2
S3üf02/110/1000A/690V 3
S3üf02/110/1250A/690V 3
S3üf02/110/800A/690V
S3üf02/110/1000A/690V –
Max. fusibles Calibre max. Non-
classe
du disjonc-
RK5 & J
teur
30A
35A
35A
40A
40A
50A
70A
80A
100A
125A
125A
150A
150A
150A
200A
250A
350A
350A
500A
600A
600A
700A
600A
800A
800A
1000A
1200A
Tension de
Contac-
commande
teur
Fusibl. Consom.
DC 1
Taille
VA
A
40
1
18
CL02
50
1
18
CL03
80
1
18
CL04
100
1
18
CL45
125
2
55
CL07
160
2
55
CL08
200
2
55
CL09
250
2
55
CK75
315
2
78
CK08
550
2
78
CK95
630
4
118
CK10
800
4
118
CK11
1000
4
118
CK12
1250
4
248
CK12
4
248
CK13
4
248
CK13
40
1
18
CL01
50
1
18
CL02
80
1
18
CL03
100
1
18
CL04
125
2
55
CL06
160
2
55
CL07
200
2
55
CL08
250
2
55
CL10
315
2
78
CK75
550
2
78
CK85
630
4
118
CK95
800
4
118
CK10
1000
4
118
CK11
1250
4
248
CK12
4
248
CK13
4
248
CK13
Valeur de court-circuit max. @480V
combi- Combi-
naison
naison
Remarques
25kA
5kA
(3) Adapté à l'utilisation sur un circuit ne
25kA
5kA
pouvant pas fournir plus de 100kA RMS
25kA
5kA
ampères symétriques, pour 208V, 240V et
25kA
5kA
jusqu'à 480V maximum, quand il est
25kA
10kA
utilisé avec le fusible semi-conducteur
25kA
10kA
pour une protection contre les court-
25kA
10kA
circuits. Repris dans le formulaire 101
25kA
10kA
Gould Shawmut, type A5QS ou A50P
65kA
25kA
(4) Adapté à l'utilisation sur un circuit ne
65kA
25kA
pouvant pas fournir plus de 65kA RMS
65kA
25kA
ampères symétriques, pour 208V, 240V et
65kA
25kA(4)
jusqu'à 480V maximum, quand il est
65kA
30kA(4)
utilisé des contacteurs (isolation ou by-
65kA
30kA
pass) admettant également 65kA.
65kA
65kA
ASTATplus
Contac-
Section
teur
conducteur
DC 3 (1)
2
VA
mm
CL02
4
CL03
4
CL03
6
B
CL04
10
CL45
16
27
CL06
25
CL06
35
CL07
50
CL10
95
CK85
185
CK85
240
(2)
CK95
Jeu de barre
CK10
Jeu de barre
(2)
CK10
Jeu de barre
(2)
CK11
Jeu de barre
(2)
(2)
CK12
Jeu de barre
CL01
4
CL02
4
CL03
4
CL04
6
CL04
10
CL04
16
CL06
25
CL06
35
CL07
70
CK75
120
CK85
185
CK85
240
(2)
CK95
Jeu de barre
CK10
Jeu de barre
(2)
CK10
Jeu de barre
(2)
(2)
CK12
Jeu de barre
)
(2) Selon CEI 60947-1

Publicité

Table des Matières
loading