IX. INSTALLING THE CEILING ASSEMBLY (9400 SERIES)
Make sure that you have properly matched the roof top air
conditioner and interior ceiling assembly. The following
step-by-step instructions must be performed in the following
sequence to insure proper installation.
A.
Remove ceiling assembly from carton, separate
individual items and remove the two grilles and
filters from the ceiling shroud.
B.
Fasten the duct collar to the air conditioner basepan
with 3 provided screws (See Figure 11).
FIGURE 9
C.
With non-metallic sheath cables (romex, etc.)
supply wiring, strip sheath to expose
approximately 40mm of supply leads. Strip
individual wire lead ends back 10mm for wire
connections.
D.
Raise the ceiling assembly chute and insert the
supply wiring through the cable clamp so there
is sufficient supply conductor to reach the power
connection strip. Secure the cable clamp over the
supply wire sheath so that no movement is
possible (See Figure 10).