INSTALLATION INSTRUCTIONS
FOR
8000 SERIES
AIR CONDITIONERS
CLIMATISEURS
SÉRIE 8000
INSTRUCTIONS D'INSTALLATION

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Airxcel RVP 8000 Serie

  • Page 1 All manuals and user guides at all-guides.com INSTALLATION INSTRUCTIONS 8000 SERIES AIR CONDITIONERS CLIMATISEURS SÉRIE 8000 INSTRUCTIONS D’INSTALLATION...
  • Page 2: Table Des Matières

    All manuals and user guides at all-guides.com TABLE OF CONTENTS General Information ............Air Conditioning Sizing .
  • Page 3: Air Conditioning Sizing

    All manuals and user guides at all-guides.com II. AIR CONDITIONING SIZING The ability of an air conditioner to provide a comfortable As a general rule, air supplied (discharge air) from the air environment for the consumer is dependent upon the conditioner will be 15 to 20 degrees cooler than the air following conditions.
  • Page 4 All manuals and user guides at all-guides.com Once the location for your air conditioner has been The frame must provide an opening to allow passage determined (See Section III), a reinforced and framed roof for the power supply wiring. Route the supply hole opening must be provided (may use existing vent hole).
  • Page 5 All manuals and user guides at all-guides.com If the roof of the vehicle is sloped (not level) such that the roof top air conditioner cannot be mounted within the maximum allowable degree deviations, an exterior leveling shim will need to be added to make the roof top air conditioner level.
  • Page 6: Securing The Air Conditioner To The Roof

    All manuals and user guides at all-guides.com V. SECURING THE AIR CONDITIONER TO THE ROOF A mounting frame is supplied with the ceiling assembly. Proper tension has been achieved for each bolt Follow the steps below to secure the air conditioner to the when any portion of each gasket indicating tab has roof.
  • Page 7: Electrical Wiring

    All manuals and user guides at all-guides.com VI. ELECTRICAL WIRING ROUTING 115 VAC WIRING THIS COULD RESULT IN PINCHING THROUGH THE PLASTIC WIRE Following RV Products high voltage wiring specifications INSULATION AND CAUSE SHORTING and all local and national electrical codes, route the roof top OR “HOT”...
  • Page 8: Installing The Ceiling Assembly (8000 Series)

    All manuals and user guides at all-guides.com The Following Two Sections Pertain Only To 8000 Series Ceiling Assemblies VII. INSTALLING THE CEILING ASSEMBLY (8000 SERIES) Place metal flange in discharge duct opening, NOTE trapping fabric between it and the ceiling assembly The optional Elect-A-Heat is intended to take the chill out of (See Figure 6).
  • Page 9 All manuals and user guides at all-guides.com FIGURE 6...
  • Page 10: Completing The Installation (8000 Series)

    All manuals and user guides at all-guides.com VIII. COMPLETING THE INSTALLATION (8000 SERIES) To complete the installation and system checkout Reinstall the ceiling shroud (secure with two screws requirements, the following steps must be performed. provided by RV Products). Put the control knobs (found in single parts package) on the selector Check the thermostat probe position.
  • Page 11 All manuals and user guides at all-guides.com Install the provided cable clamp in the 7/8" dia. hole Raise the ceiling assembly and secure to the on the back of the metal field wiring box. Insert the mounting frame with 4 provided shoulder supply wiring through the cable clamp and into the screw/spring assemblies.
  • Page 12: Completing The Installation (9000 Series)

    All manuals and user guides at all-guides.com FIGURE 14 FIGURE 15 X. COMPLETING THE INSTALLATION (9000 SERIES) Make sure the non-allergenic filters are properly System Checkout - RV Products manufactures a positioned in the ceiling grille. wide range of roof top air conditioners which incorporate different product operation features.
  • Page 13: Renseignements Généraux

    All manuals and user guides at all-guides.com TABLE DES MATIÈRES Renseignements généraux ............Configuration du climatiseur .
  • Page 14: Configuration Du Climatiseur

    All manuals and user guides at all-guides.com II. CONFIGURATION DU CLIMATISEUR La capacité du climatiseur de fournir au client un Par exemple, si l’air qui entre dans le climatiseur (l’air environnement confortable dépend des conditions suivantes. recyclé) est de 80 degrés Fahrenheit (27 degrés Celsius) l’air d’alimentation (air de décharge) dans le véhicule sera de 60 à...
  • Page 15: Installation De L'appareil Sur Le Toit

    All manuals and user guides at all-guides.com IV. INSTALLATION DE L’APPAREIL SUR LE TOIT véhicule. Attention en coupant l’ouverture du DANGER CHOC ÉLECTRIQUE plafond. Si cette ouverture est recouverte de tapis, il pourrait y avoir des accrocs. Après avoir une COUPEZ TOUT COURANT AU VÉHICULE AVANT ouverture à...
  • Page 16: Fixer Le Climatiseur Au Toit

    All manuals and user guides at all-guides.com une cale de mise à niveau typique. Après avoir préparé correctement la région de l’ouverture d’installation, retirez le carton et les blocs d’expédition du climatiseur de toit. Soulevez délicatement l’appareil sur le dessus du véhicule. N’utilisez pas le carénage extérieur de plastique pour soulever.
  • Page 17: Installation Du Montage De Plafond (Série 8000)

    All manuals and user guides at all-guides.com NORMALEMENT D’UNE LÉGÈRE DANGER PRESSION. DANGER DE CHOC ÉLECTRIQUE SI VOUS UTILISEZ DES CÂBLES AUTRES POUR ÉVITER LA POSSIBILITÉ DE QUE LES CÂBLES NON-MÉTALLIQUES BLESSURES SUITE À DES CHOCS COMME CONDUCTEURS ÉLECTRIQUES, LE FIL BLANC DOIT D’ALIMENTATION, VOUS DEVEZ ÊTRE CONNECTÉ...
  • Page 18: Fin De L'installation (Série 8000)

    All manuals and user guides at all-guides.com Prenez le conduit électrique du climatiseur de toit et boîte decommandu du sélecteur. Utilisez un ruban raccordez-le à l’arrière de la boîte de commande du d’électricité approuvé U.L. et fixez les écrous de thermostat.
  • Page 19 All manuals and user guides at all-guides.com Déballez avec soin le montage de plafond. Les deux trous de l’écran sont alignés avec les trous des commandes sont installées en usine dans le montage deux vis dans le guide du montage de plafond (voir de plafond (sauf les montages pour les applications figure 12).
  • Page 20: Fin De L'installation (Série 9000)

    All manuals and user guides at all-guides.com X. FIN DE L’INSTALLATION (SÉRIE 9000) Assurez-vous que les filtres non allergènes sont bien Vérification du système - RV Products fabrique une installés dans la grille du plafond. vaste gamme de climatiseurs de toit qui incorpore différentes fonctions d’exploitation du produit.
  • Page 21 All manuals and user guides at all-guides.com RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976G256 (1-02) PP...