TROUBLESHOOTING GUIDE

Problem
Won't power up. (No response
when buttons are pressed.)
Won't start cycle when Start
button is pressed.
Won't shut off when expected.
Control won't accept selections.
Won't heat.
Heats in air cycle.
Shuts off before clothes are dry.
Steam Models Only:
Water not dispensing.
Some tests will require accessing components.
Possible Cause/Test
NOTE: Possible Cause/Tests MUST be performed
in the sequence shown for each problem.
1. Supply connections. See TEST #1, page 12.
2. Unplug dryer or disconnect power. Check
harness connections.
3. User interface and housing assembly.
See TEST #5, page 20.
1. If number display flashes, check to be sure the
door is completely shut, and press and hold down
START for about 1 second.
2. See TEST #2, page 14.
3. See TEST #6, page 20.
1. Check START/PAUSE button.
2. User interface and housing assembly.
See TEST #5, page 20.
3. Moisture sensor. See TEST #4, page 18.
User interface and housing assembly.
See TEST #5, page 20.
1. Check installation.
2. Unplug dryer or disconnect power. Check
harness connections.
3. Heater. See TEST #3, page 15.
Heater. See TEST #3, page 15.
1. Check the dryness (dryness level on Maytag
models) setting for auto cycles.
2. Check for full lint screen.
3. Check for clogged vent.
4. Moisture sensor. See TEST #4, page 18.
5. Dryness (dryness level on Maytag models) adjust.
See TEST #4a, page 19.
1. Make sure a "Steam" cycle is selected.
2. See TEST #7, page 21.
PAGE 11