FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY
USER INTERFACE/
CONTROL SYSTEM TEST
Entry Procedure:
Press and release the first button used to activate
Service Diagnostic mode. The following tests will
be available.
NOTE: The Service Diagnostic mode must be
activated before activating the User Interface/
Control System test; see procedure on page 2.
Active Fault Code Display in User
Interface/Control System Test:
If the display (on models with seven segment
display) or WET indicator (on models without
seven segment display) begins flashing while in
User Interface/Control System test, it is displaying
an active fault code. Active fault codes are codes
that are currently failing. Only one active fault
code can be displayed at a time.
Diagnostic Test: Console Buttons
and Indicators
(models with seven segment display
and some models without seven
segment display)
Pressing buttons and rotating the cycle selector
will turn off the corresponding indicator and
sound a beep as shown in figure 1, Console
Diagnostics. If indicators fail to come on and beep
after pressing buttons and rotating the cycle
selector, go to TEST #5, page 20.
(model 9150 without seven
segment display)
Pressing buttons will turn off the corresponding
indicator and sound a beep as shown in figure 1,
Console Diagnostics. Rotating the cycle selector
will cause the status indicators to display the
index of the cycle selector. See table below for
details. If indicators fail to come on and beep after
pressing buttons and rotating the cycle selector,
go to TEST #5, page 20.
Status
Indicator
Delicate
"ON"
Wet
Damp
"ON"
Cool Down
"ON"
Done
"OFF"
Status
Indicator
Wet
Damp
Cool Down
Done
Casual
"ON"
"ON"
"ON"
"ON"
60 min
"ON"
"OFF"
"OFF"
"ON"
PAGE 5
(all models)
NOTE: A second press of the POWER (POWER/
CANCEL on Maytag models) button while in
Console Buttons and Indicators mode exits the
Service Diagnostic mode and returns the dryer
to standby mode.
Diagnostic Test: Door Switch
(models with seven segment display)
Opening the door should cause a beep and an
alphanumeric number to be displayed. Closing
the door should cause a beep and
displayed.
If opening the door fails to cause a beep and
an alphanumeric number to be displayed, go
to TEST #6, page 20.
(models without seven segment display)
When the door is opened, for electric dryers, the
dryer will beep once and the WET status indicator
will turn on. For gas dryers, the dryer will beep
twice and the DONE or COMPLETE (depending on
model) status indicator will turn on. With the door
open, the TEMP indicators will be used to display
the Control Software ID. The TEMP indicators will
be "On" or "Off" according to the table below.
Temp Indicators
High
Medium
Low
Air Dry
If opening the door fails to cause a beep(s),
Control Software ID, or fuel type to be indicated,
go to TEST #6, page 20.
AUTO CYCLE
Normal
Eco Normal
"OFF"
"OFF"
"OFF"
"OFF"
TIMED CYCLE
40 min
"ON"
"OFF"
"OFF"
"OFF"
88
to be
Temp Indicators
or
Heavy Duty
"OFF"
"OFF"
"OFF"
"OFF"
"OFF"
"ON"
"ON"
"OFF"
Small Load
"OFF"
"ON"
"ON"
"ON"