Maintenance; Safety Instructions; Bmaintenance Plan; Daily Maintenance - Cassese CS 200 CART Manuel De L'utilisateur

Masquer les pouces Voir aussi pour CS 200 CART:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

USER MANUAL

5 MAINTENANCE

5.A

SAFETY INSTRUCTIONS

The CS200 CART is using pneumatic air supply. It is essential for your safety to make sure that it is
disconnected prior to make any maintenance. Please refer to instructions below prior to perform any
maintenance.
Rotate red button in EXH position.
Unplug the machine from pneumatic source.
Install a locker to ensure nobody will turn back on the machine while you will be
performing the maintenance.
If using compressed air to clean some parts, wear safety glasses. It is even recommended to use a vacuum to
5.B
MAINTENANCE PLAN
5.B.a

Daily maintenance:

It is recommended once a day to clean the table surface with a clean cloth and make sure there is no debris in the distributor
head. If some glue is remaining in the distribution block, then perform procedure 5.C REMOVING THE DISTRIBUTOR HEAD (page
20) and 5.D LUBRICATING THE DISTRIBUTOR HEAD (page 21). It is important to avoid glue from drying in the distribution head
as it could prevent the cartridge from going in the distribution block correctly.
5.B.b

Regular maintenance:

Once a week it is recommended to clean and lubricate the distribution block. Refer to following chapter to perform this
maintenance:
5.A
SAFETY INSTRUCTIONS
(page: 19)
5.C REMOVING THE DISTRIBUTOR HEAD (page 20)
5.D LUBRICATING THE DISTRIBUTOR HEAD (page 21)
clean the machine rather than compressed air that will spray dust everywhere.
All maintenance and control operations must be carried out by skilled maintenance staff.
CS200 CART
Figure 5-1
19

Publicité

Table des Matières
loading

Table des Matières