USER & PARTS MANUAL

6 MAINTENANCE

When the cover is opened, a safety sensor prevents the starting of the motors.
6.A

OPENING THE COVER

Press the pedal to
release the clamps as
the
vertical
clamps
can avoid the opening
of the cover if they are
in down position.
Still
with
the
pedal
pressed,
unlock
the
right clamp.
Before performing any maintenance , switch off the main electrical contactor (12) and the air rotating switch (15)
and lock it with a locker.
6.B

REPLACEMENT OF THE BLADES

Before performing any maintenance , switch off the main electrical contactor (12) and the air rotating switch (15)
and lock it with a locker.
Allen key N.6
Allen key N.10
Figure 6-1
Figure 6-3
During that operation it is important to wear protecting gloves to avoid personal injuries.
Keep
the
pedal
pressed and unlock
the left and front cover
clamps.
Open the cover and tilt
it on top of the machine.
Protecting gloves
CS940
Figure 6-2
Figure 6-4