RATING PLATE INFORMATION

CONFORMS TO / CONFORME AUX: ANSI Z21.50-2014, CERTIFIED TO / CERTIFIE CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM INSTALLATION. SUITABLE
FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT
STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA
OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND
SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT
APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFAC-
TURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A. FOR
USE WITH BARRIER W010-3295. FOLLOW THE INSTALLATION INSTRUCTIONS
LOCATED IN THE INSTALLATION MANUAL
MANIFOLD PRESSURE: 3.5" W.C. (NG)
PRESSION AU COLLECTEUR: 3.5" D'UNE
COLONNE D'EAU(GN)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN: 4.5"
D'UNE COLONNE D'EAU (GN)
MAX. SUPPLY PRESSURE: 7" W.C. (NG)
PRESSION D'ALIMENTATION MAX: 7"
D'UNE COLONNE D'EAU (GN)
AFUE: 64%
NOT FOR USE WITH SOLID FUEL
FOR USE WITH GLASS DOORS CERTIFIED
WITH THIS UNIT ONLY.
WARNING: DO NOT ADD ANY MATERIAL TO
THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN
THAT SUPPLIED BY THE MANUFACTURER
WITH THE APPLIANCE.
ELECTRICAL RATING: 115V 1.5AMP 60HZ
THE APPLIANCE MUST BE VENTED USING
THE APPROPRIATE WOLF STEEL VENT
KITS. SEE OWNERS INSTALLATION MANUAL
FOR VENTING SPECIFICS. MINIMUM AND
MAXIMUM VERTICAL VENT LENGTHS ARE 3
FEET AND 40 FEET RESPECTIVELY.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE. ONTARIO L4M 0G8 CANADA
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to the
model, venting and gas type of the unit.
For rating plate location, see "INSTALLATION OVERVIEW" section.
This illustration is for referece only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and shall be installed.
9700539 (WSL)
4001658 (NAC)
GDS25N
0-2000ft
2000-4500ft
ALTITUDE / ELEVATION
24,500 BTU/h
22,000 BTU/h
INPUT / ALIMENTATION
19,000 BTU/h
16,000 BTU/h
REDUCED INPUT /
ALIMENTATION REDUITE
MINIMUM AND MAXIMUM HORIZONTAL
ONTAL
VENT LENGTHS ARE 10 INCHES AND 20
AND 20
FEET RESPECTIVELY. PROPER REINSTAL-
EINSTAL-
LATION AND RESEALING IS NECESSARY
ARY
AFTER SERVICING THE VENT-AIR INTAKE
E VENT-AIR INTAKE
SYSTEM.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL:
NCE TO COMBUSTIBLE MATERI
A
4"
B
2"
2
C
2"
2"
VENT TOP
ENT TOP
2"
2"
TO CEILING FROM
TO
VENT BOTTOM
VENT BOTTOM
1"
1"
S
STOVE TOP
VENT SIDES
ENT SIDES
1"
M 0G8 CANA
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE BAIN ET
DANS UN
UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON
R INSTALLATI
INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE
RME AUX EXIGENCE
MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS
EQUIPEES AU GAZ, EN VIG
DE LA NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES,
CURITE ET DE CONSTRUCT
TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT
3280. DANS LE CAS OU C
ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE
ERER A LA NORME
SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS
CONTRE L'INCENDIE POUR LE
MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A. POUR UNE
ACTURES, LES SITES ET LES CO
UTILISER AVEC BARRIÈRE W010-3295. SUIVEZ LES INSTRUCTIONS D'INSTALLATION
ER AVEC
W010-3295
4001657 (NGZ)
4001657 (NGZ)
4001659 (WUSA)
4001659 WUSA)
GDS25P
GDS25P
MODEL
ELEVATION
0-2000ft
0-2000ft
LIMENTATION
23,000 BTU/h
UCED INPUT /
16,000 BTU/h
ENTATION REDUITE
UN COMBU
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE
UTILSE A
UTILSE AVEC CET APPAREIL
UTILISER
UTILISER AVEC LES PORTES VITREES
HOMOL
HOMOLOGUEES SEULEMENT AVEC CETTE
UNITE.
UN
AV
AVERTISSEMENT: N'AJOUTEZ PAS A CET
APPAREIL AUCUN MATERIAU DEVANT
ENTRER EN CONTACT AVEC LES FLAMMES
AUTRE QUE CELUI QUI EST FOURNI AVEC
CET APPAREIL PAR LE FABRICANT.
CLASS.: 115V 1.5AMP 60HZ L'APPAREIL
DOIT EVACUER SES GAZ EN UTILISANT
L'ENSEMBLE D'EVACUATION PROPRE A
WOLF STEEL. REFERER AU MANUEL
D'INSTALLATION DE PROPRIETAIRE POUR
L'EVACUATION PRECISE. LES LONGUEURS
48"
VERTICALES MINIMALES ET MAXIMALES
SONT3 PIEDS ET 40 PIEDS
RESPECTIVEMENT.
GDS25
SERIAL NUMBER / NO. DESERIE
PLACE
SE TROUVENT DANS LE MANUEL D'INSTALLATION.
MANIFOLD PRESSURE: 10" W.C. (LP)
PRESSION AU COLLECTEUR: 10" D'UNE
COLONNE D'EAU(P)
MIN SUPPLY PRESSURE: 11" W.C.(LP)
2000-4500ft
PRESSION D'ALIMENTATION MIN: 11"
20,000 BTU/h
D'UNE COLONNE D'EAU (P)
MAX. SUPPLY PRESSURE: 13" W.C. (LP)
14,000 BTU/h
PRESSION D'ALIMENTATION MAX: 13"
D'UNE COLONNE D'EAU (P)
AFUE: 64%
LES LONGUEURS HORIZONTALES MINIMALES ET
MAXIMALES SONT 10 POUCES ET 20 PIEDS
RESPECTIVEMENT.
IL EST IMPORTANT DE BIEN REINSTALLER ET
RESCELLER L'EVENT APRES AVOIR ASSURE LE
MAINTIEN DU SYSTEME DE PRISE D'AIR.
DEGAGEMENTS MINIMAUX DES MATERIAUX
COMBUSTIBLES:
A
4"
B
2"
C
2"
EVENT SUPERIEUR
2"
ENTRE LE DESSUS
DU FOYER
EVENT INFERIEUR
1"
ET LE PLAFOND
COTES DE L'EVENT
1"
W385-1962
W415-1332 / A / 11.21.14
7
EN
48"