Information Sur La Plaque D'homologation - Napoleon GDS25N Instructions D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.4

INFORMATION SUR LA PLAQUE D'HOMOLOGATION

CONFORMS TO / CONFORME AUX: ANSI Z21.50-2014, CERTIFIED TO / CERTIFIE CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM INSTALLATION. SUITABLE
FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT
STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA
OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND
SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT
APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFAC-
TURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A. FOR
USE WITH BARRIER W010-3295. FOLLOW THE INSTALLATION INSTRUCTIONS
LOCATED IN THE INSTALLATION MANUAL
MANIFOLD PRESSURE: 3.5" W.C. (NG)
PRESSION AU COLLECTEUR: 3.5" D'UNE
COLONNE D'EAU(GN)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN: 4.5"
D'UNE COLONNE D'EAU (GN)
MAX. SUPPLY PRESSURE: 7" W.C. (NG)
PRESSION D'ALIMENTATION MAX: 7"
D'UNE COLONNE D'EAU (GN)
AFUE: 64%
NOT FOR USE WITH SOLID FUEL
FOR USE WITH GLASS DOORS CERTIFIED
WITH THIS UNIT ONLY.
WARNING: DO NOT ADD ANY MATERIAL TO
THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN
THAT SUPPLIED BY THE MANUFACTURER
WITH THE APPLIANCE.
ELECTRICAL RATING: 115V 1.5AMP 60HZ
THE APPLIANCE MUST BE VENTED USING
THE APPROPRIATE WOLF STEEL VENT
KITS. SEE OWNERS INSTALLATION MANUAL
FOR VENTING SPECIFICS. MINIMUM AND
MAXIMUM VERTICAL VENT LENGTHS ARE 3
FEET AND 40 FEET RESPECTIVELY.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE. ONTARIO L4M 0G8 CANADA
INSTALLATEUR : Il est de votre responsabilité de cocher, sur la plaque d'homologation, les cases
correspondant au modèle, au type d'évacuation et au type de gaz de l'appareil.
Pour l'emplacement de la plaque d'homologation, voir la section « VUE D'ENSEMBLE DE L'INSTALLATION ».
Cette illustration est fournie à titre indicatif seulement. Pour les renseignements exacts, consultez la plaque
d'homologation fi xée sur l'appareil.
NOTE: Le plaque d'homologation doit rester avec l'appareil à tout le temps. Il ne doit pas être enlevé.
Une barrière conçu à réduire le risque de brûlures à partir de le chaude la vitre est à condition que avec
l'appareil et sera être installés.
9700539 (WSL)
4001658 (NAC)
GDS25N
0-2000ft
2000-4500ft
ALTITUDE / ELEVATION
24,500 BTU/h
22,000 BTU/h
INPUT / ALIMENTATION
19,000 BTU/h
16,000 BTU/h
ALIMENTATION REDUITE
MINIMUM AND MAXIMUM HORIZONTAL
TAL
VENT LENGTHS ARE 10 INCHES AND 20
20
FEET RESPECTIVELY. PROPER REINSTAL-
ER REINSTAL-
LATION AND RESEALING IS NECESSARY
S NECESSAR
AFTER SERVICING THE VENT-AIR INTAKE
NT-AIR INTAKE
SYSTEM.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL:
ANCE TO COMBUST
A
4"
B
2"
2"
C
2"
VENT TOP
NT TOP
2"
2"
TO CEILING FROM
VENT BOTTOM
ENT BOTTOM
1"
STOVE TOP
VENT SIDES
VENT SIDES
1"
RIE. ONTARIO L4M 0G
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE BAIN ET
UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON
INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE
ME AUX EXIGENCES D
MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS
UIPEES AU GAZ, EN V
DE LA NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES,
URITE ET DE CO
TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT
N 3280. DANS LE
ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE
EFERER A LA
SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS
CONTRE L'INCENDIE P
MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A. POUR UNE
URES, LES SITES
UTILISER AVEC BARRIÈRE W010-3295. SUIVEZ LES INSTRUCTIONS D'INSTALLATION
EC BARRIÈRE W
400165
4001657 (NGZ)
4001659 (WUSA)
4001659 (WUSA)
MODEL
GDS25
GDS25P
LEVATION
0-20
0-2000ft
MENTA
23,000 BTU/h
REDUCED INPUT /
CED INPUT
16,000 BTU/h
NTATION REDU
UN CO
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE
UTILSE AVEC CET APPAREIL
UTILISER AVEC LES PORTES VITREES
HOMOLOGUEES SEULEMENT AVEC CETTE
UNITE.
AVERTISSEMENT: N'AJOUTEZ PAS A CET
APPAREIL AUCUN MATERIAU DEVANT
ENTRER EN CONTACT AVEC LES FLAMMES
AUTRE QUE CELUI QUI EST FOURNI AVEC
CET APPAREIL PAR LE FABRICANT.
CLASS.: 115V 1.5AMP 60HZ L'APPAREIL
DOIT EVACUER SES GAZ EN UTILISANT
L'ENSEMBLE D'EVACUATION PROPRE A
WOLF STEEL. REFERER AU MANUEL
D'INSTALLATION DE PROPRIETAIRE POUR
L'EVACUATION PRECISE. LES LONGUEURS
48"
VERTICALES MINIMALES ET MAXIMALES
SONT3 PIEDS ET 40 PIEDS
RESPECTIVEMENT.
GDS25
SERIAL NUMBER / NO. DESERIE
ACE / FOYER À GA
S UNE CHAMBRE A
INSTALLATION
SE TROUVENT DANS LE MANUEL D'INSTALLATION.
MANIFOLD PRESSURE: 10" W.C. (LP)
PRESSION AU COLLECTEUR: 10" D'UNE
COLONNE D'EAU(P)
MIN SUPPLY PRESSURE: 11" W.C.(LP)
2000-4500ft
PRESSION D'ALIMENTATION MIN: 11"
20,000 BTU/h
D'UNE COLONNE D'EAU (P)
MAX. SUPPLY PRESSURE: 13" W.C. (LP)
14,000 BTU/h
PRESSION D'ALIMENTATION MAX: 13"
D'UNE COLONNE D'EAU (P)
AFUE: 64%
LES LONGUEURS HORIZONTALES MINIMALES ET
MAXIMALES SONT 10 POUCES ET 20 PIEDS
RESPECTIVEMENT.
IL EST IMPORTANT DE BIEN REINSTALLER ET
RESCELLER L'EVENT APRES AVOIR ASSURE LE
MAINTIEN DU SYSTEME DE PRISE D'AIR.
DEGAGEMENTS MINIMAUX DES MATERIAUX
COMBUSTIBLES:
A
4"
B
2"
C
2"
EVENT SUPERIEUR
2"
ENTRE LE DESSUS
DU FOYER
EVENT INFERIEUR
1"
ET LE PLAFOND
COTES DE L'EVENT
1"
W385-1962
W415-1332 / A / 11.28.14
55
FR
48"