Maintenance; Annual Maintenance - Napoleon GDS25N Instructions D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

34
10.0

MAINTENANCE

EN
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.
APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after servicing. This appliance and its venting system
should be inspected before use and at least annually by a qualifi ed service person. The appliance area must
be kept clear and free of combustible materials, gasoline or other fl ammable vapors and liquids. The fl ow of
combustion and ventilation air must not be obstructed.
In order to properly clean the burner and pilot assembly, remove the logs, rocks and/or glass to
A.
expose both assemblies.
Keep the control compartment, media, burner, air shutter opening and the area surrounding the logs
B.
clean by vacuuming or brushing, at least once a year.
Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or
C.
are not burning properly.
Check to see that the pilot fl ame is large enough to engulf the fl ame sensor and/or thermocouple /
D.
thermopile as well as reaches the burner.
Replace the cleaned logs, rocks or glass. Failure to properly position the media may cause carboning
E.
which can be distributed in the surrounding living area.
Check to see that the main burner ignites completely on all openings when turned on. A 5 to 10
F.
second total light-up period is satisfactory. If ignition takes longer, consult your local authorized dealer /
distributor.
Check that the gasketing on the sides, top and bottom of the door is not broken or missing. Replace if
G.
necessary.
If for any reason the vent air intake system is disassembled, re-install and re-seal per the instructions
H.
provided for the initial installation.
Cleaning the safety barrier may be necessary due to excessive lint / dust from carpeting, pets, etc.
I.
simply vacuum using the brush attachment.
Ensure the relief system performs effectively. Check that the gasket is not worn or damaged. Replace
J.
if necessary.

10.1 ANNUAL MAINTENANCE

THE FIREBOX BECOMES VERY HOT DURING OPERATION. LET THE APPLIANCE COOL
COMPLETELY OR WEAR HEAT RESISTANT GLOVES BEFORE CONDUCTING SERVICE.
This appliance will require maintenance which should be planned on an annual basis.
Service should include cleaning, battery replacement, venting inspection and inspection of the burner,
media and fi rebox. Refer to the door removal section and remove the door as instructed.
Carefully remove media if necessary (logs, glass, brick panels etc).
Using a vacuum with a soft brush attachment, gently remove any dirt, debris or carbon build up from the
logs, fi rebox and burner. For glass media, follow the installation instructions for pre-cleaning.
Also gently remove any build-up on the pilot assembly including, if equipped; thermopile, thermocouple,
fl ame sensor and igniter. NOTE: The fl ame sensor may require to be cleaned using a fi ne steel wool or
Scotch-Brite™ scrubbing pad to remove any oxides. Clean the pilot assembly using a vacuum with a
soft brush attachment. It is important that the pilot assembly is not painted.
Inspect all accessible gaskets and replace as required.
W415-1332 / A / 11.21.14
MAINTENANCE
MAINTENANCE
WARNING
MAINTENANCE
!
DO NOT USE ABRASIVE CLEANERS.
DO NOT PAINT THE PILOT ASSEMBLY.
WARNING
!
NEVER VACUUM HOT EMBERS.
DO NOT PAINT THE PILOT ASSEMBLY.
40.1D

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Gds25pGds25nsb

Table des Matières