9.3

FLAME CHARACTERISTICS

It's important to periodically perform a visual check of the pilot and burner
fl ames. Compare them to the illustrations provided. If any fl ames appear
abnormal call a service person.
9.4

ANTI CONDENSATION SWITCH

This appliance has the option to change from an
electronic intermittent pilot ignition (IPI) to a standing
pilot for cold climates. The anti condensation control
(standing pilot) is located in the center of the control
panel. Using your fi nger, fl ip the switch up for
standing pilot, or down for intermittent pilot ignition.
Turning the ACS switch on will allow the pilot
fl ame burning to burn continuously. This mode will
minimize the condensation which forms on the inside
of the glass when the main burner is fi rst turned on.
It will also help the fi replace and vent system more
quickly during the colder winter months.
During the warmer winter and summer months,
the ACS switch can be turned off to minimize fuel
consumption.
54.3
CONTROL
PANEL
OPTIONAL ANTI CONDENSATION
SWITCH (ACS)
33