ENGLISH
TEMPERATURE
1. Insert K-type thermocouple into the VΩµA
(observe polarity markings on thermocouple and meter), and rotate
function selector switch
NOTE: The meter defaults to Fahrenheit scale in this mode. To enter
Celsius scale, press the "SELECT" button
appropriate icon (either °F or °C ) appears on the display.
2. To measure temperature, make contact between the
thermocouple tip and the object being measured. When
thermocouple tip and object are in thermal equilibrium, the
measurement on the display will stabilize.
Remove thermocouple before switching meter to other
measurement functions.
The thermocouple included with the original purchase is
suitable for temperatures below 446°F / 230°C only.
To measure higher temperatures, a K-type thermocouple
with the appropriate measurement range should be used.