ENGLISH
OPERATING INSTRUCTIONS
AC CURRENT (LESS THAN 400A)
AC Current is measured by pressing the clamp trigger
to open
10
the clamp and placing it around a current-carrying wire. When
measuring, care should be taken to ensure that the clamp is
completely closed with trigger
fully released, and that the wire
10
passes perpendicularly through the center of the clamp in line with
the arrow markings
.
11
To measure current:
1. Rotate the Function Selector switch
2
to the 40/400 A setting.
2. Place clamp around wire. The current measurement will be shown
in the display.
NOTE: If the measurement is less than 40A, rotate the Function
Selector switch
to the 4A setting for improved resolution. If the
2
measurement is less than 4A, the meter will auto-range to the 4A
range.
Disconnect test leads when measuring with the clamp.