7. Transmission losses

Sometimes transmission losses may arise, indicated by missing
temperature data in the sensor's curve display.
Data losses may be caused by:
1.
Problems inside the transceiver
2.
Problems in the sensor module
3.
Problems in the signal transfer between temperature sensor
module and transceiver
7.1. Problems inside the transceiver
The transceiver does not registrate a single data signal, even if the
sensor is located at a minimum distance to the receiver.
Potential problems:
-
USB-cable between receiver and computer is missing or defect
-
Improper installation of the USB driver
-
Unknown software problem in the computer system
Internal battery is empty (replace the battery)
-
Suggested solutions:
-
Check (under: Start > Configuration> Devices and printers)
if there is an RF-USB device.
-
Install the driver again, only connect the device when the instal
software asks for it.
-
Remove the USB-cable, wait about ten seconds and reconnect
the cable.
-
Deinstall the temperature logger application software and
reinstall it again.
Extra information and possible updates can be found on www.arexx.com
Further questions can also be put on our forum, see www.arexx.com