Throttle Cable Connection - Ultraflex B 501 CH/B Manuel D'installation Et D'entretien

Manette mono-levier
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ULTRAFLEX
7
Engage the rod
(15) on the pin (I).
WARNING
Check the right setting of shift cable stroke and make sure that is compliant with the following conditions.
During the shift engagement, the lever movement must be always fluid with a constant resistance.
The lever must no become stiffer during the throttle engagement, otherwise check that the control shift
stroke corresponds to the engine one.

3.5.2 Throttle cable connection

1
Remove the cable fastener (8) from the plate
(9) removing the screws (10).
10
3
CONTROL B502: Unthighten not completley
the M5 screw (17) without disconnecting. The cable
clamp (18) becomes loose letting pass the cable
fixing elements.
17
18
page 12
of 71 -
SINGLE LEVER CONTROL B501 AND B502
15
I
2
cylinder (11) is placed inside the plate hole (16).
9
8
4
After turning upside down the control, mount the
cable making sure the cable cylinder (19) is placed
inside the plate hole.
Installation and maintenance manual
8
Mount the plate
(H) in the way shown
in the picture and fix
it with the screw (G)
on the hole (16).
Mount the cable making sure the cable
11
CONTROL B502:
19
G
H
16
16

Publicité

Table des Matières
loading

Table des Matières